Aquatic owner manual Infinity Series Whirlpools, Bathside Control Systems

Page 15
Heater On Indicator Set Point Indicator

OPERATION of

INFINITY SERIES WHIRLPOOLS

NOTE: DO NOT START PUMP UNTIL ALL JETS ARE SUBMERGED. WATER LEVEL SHOULD BE 2" ABOVE HIGHEST JET.

BATHSIDE CONTROL SYSTEMS:

INFINITY ON/OFF WITH HEATER CONTROL (SEE DIAGRAM 6A):

1.To Turn Pump On: Pressing the On/Off button will turn the pump on. Pressing a second time will turn the pump off. A built-in timer will turn the pump and heater off after 20 minutes.

2.To Change Temperature: The heater and buttons are used to set water temperature. When pressed, the display shows the actual set point. By pressing up or down, the set point can be changed. Keeping the buttons pressed changes the setting continuously. The temperature can vary from 90° to 104° F.

Note: The set point light (sp) is “On” when the display shows the set point and “Off” when it shows the actual water temperature. The heater’s LED will blink when the system calls for heat and will stay on when the heater is “On”. The control turns the heater “On” when the temperature reaches the set point —1° F and keeps it on until it reaches the set point +1° F.

3.For Infinity I: To Turn Continuous Waterfall On: Pressing and holding down the chromatherapy button for 2 seconds will turn the continuous waterfall on. Depressing the chromatherapy button for 2 seconds with the continuous waterfall on will turn off the

waterfall. However, the light output will automatically turn off after 2 hours; the continuous waterfall will automatically turn off after 20 minutes. Note: The continuous waterfall is only featured on the Infinity I.

Other Features:

• When power is on, the control displays “000” for five seconds and then blanks itself.

• When the pump is shut off, the display shows the water temperature for a period of 15 minutes.

• The High-Limit circuit will shut the heater off if the

6A

 

temperature of the water at the High-Limit sensor

 

reaches 119° F. Should this occur, the display will

 

show “• • • ” but the pump will still be allowed to work. Only the heater will be shut off. In order for the heater to be reactivated the user must reset circuit breaker when the temperature has fallen below 119° F.

When the pump is on, the display will normally show the current water temperature reading and the remaining minutes on the timer. This will toggle every 5 seconds.

16

AQUATIC INDUSTRIES, INC.

Image 15
Contents Infinity Series Table of Contents Warranty Confirmation Owner InformationPurchase Registration Congratulations Read and Follow ALL Instructions Installation Instruction Guidelines Read ALL Instructions Carefully Before InstallationPRE-INSTALLATION Procedures Structural Preparation Installation InstructionsLeveling of the Infinity Structural PreparationFactory Installed Tile Flange PlumbingSee Illustration 2A ROUGH-IN Measurements ModelFast Fill Waterfall Spout Continuous Waterfall Infinity Electrical InstallationBlower Please see Diagrams 4A and 4B.Infinity Electronic T-HEATER Model Number HS Chromatherapy LED Lighting Infinity ON/OFF with Heater Control see Diagram 6A Infinity Series WhirlpoolsBathside Control Systems Infinity AIR Bath Control see Diagram 6C Infinity JET Sequencer Control see Diagram 6BPurge 24 Hours Infinity AIR Bath Purge Cycle see Diagram 6CJET Operations To adjust pressure see Diagram 7BTo replace or change jet see Diagram 7D To Remove/Replace Pillow see Diagram 8ATo replace or change jet see Diagram 9C To adjust pressure see Diagram 8BTo replace or change jet see Diagram 8C To adjust pressure see Diagram 9ATo replace or change jet see Diagram 11B To adjust pressure see Diagram 10ATo adjust circular pattern To adjust pressure see Diagram 11AElectrical Installation Information Listed on pages Whirlpool User InformationFCC Consumer Information AIR Bath System Cleaning Maintenance and CareInitial Cleaning Whirlpool System CleaningSurface Scratch Removal Surface CleaningJET Cleaning Water Quality IssuesChemical Quality Water Quality IssuesTreatment Symptoms Possible Problems Suggested Solutions Troubleshooting GuidePlease Fill OUT Completely Replacement Parts Order FormHow To Use Quantity Description Color/Finish PriceInfinity Series Replacement Parts Order MAPAssorted Fittings Replacement Parts Order MAP 27a 27b 28a 28b 28c F I N I T Y B a T H P a R T S L I S T Assorted Fittings Aquatic Industries, Inc. Limited Lifetime Warranty IOM6 12/05