Aquatic Infinity Series Maintenance and Care, Initial Cleaning, Whirlpool System Cleaning

Page 22

MAINTENANCE AND CARE

INITIAL CLEANING:

Before tub is used, the whirlpool system should be cleaned and disinfected. Remove all debris and clean tub before putting whirlpool into service. DO NOT USE ABRASIVE CLEANERS ON THE ACRYLIC FINISH. Use a non-abrasive detergent and rinse well after cleaning.

Fill the tub with HOT water to a level 2" above the highest jet.

Add 2 teaspoons of low-sudsing automatic dishwashing detergent and no more than 4 ounces of household bleach to the water.

Operate whirlpool for 10 minutes. Drain. Note: To effectively clean both the whirlpool and air bath system, you must operate them both. (See sections entitled “Infinity On/Off with Heater Control”

[Diagram 6A] and “Infinity Air Bath Control” [Diagram 6C], pages 16-17).

Refill with cold water and operate whirlpool for 5 minutes. Drain.

WHIRLPOOL SYSTEM CLEANING:

To remove accumulations of bath residue from the whirlpool system, we recommend that you purge it at least twice a month, or more depending on usage. To do this, follow this simple procedure. Fill the bath with hot water (not exceeding 140o F). Add to the hot water, 4 (6) tablespoons of low foaming detergent such as liquid Cascade or Calgonite and 24 (48) oz. of liquid household bleach, such as Clorox [use lesser amounts shown for 5-foot bathtubs, greater amounts in parentheses for larger bathtubs]. Run the bath for 5 to 10 minutes. Drain the bath completely and refill with cold water only. Run the whirlpool for 5 to 10 minutes, then drain the bath completely. Depending on the usage and/or the content of the local water supply, more frequent purging may be necessary.

AIR BATH SYSTEM CLEANING:

NOTE: DO NOT TURN THE PUMP ON DURING THE AIR BATH CLEANING.

Before tub is used, your air bath and plumbing system should be flushed. Close the drain. Fill bath with hot water to at least six inches above air injector holes. Add 2 teaspoons of low sudsing automatic dishwashing detergent and no more than 4 ounces of bleach to the water. DO NOT use bleach or other chlorinated cleansers on metal trim surrounding control panels. Turn blower on for approximately two minutes to mix cleaner with water. Shut blower down and allow cleaner to soak in the bath for approximately two hours. Turn ON air bath and run for approximately five minutes. Turn air bath unit OFF and drain tub. Aquatic recommends the above cleaning process on your air bath system once a month.

NOTE: DO NOT USE OIL OR OIL BASED BATH ADDITIVES.

If you want to use any kind of bath additive, use only a small amount of low-foaming powder or crystal substance; the whirlpool action intensifies the foaming properties of soaps.

The use of certain bubble baths and bath additives may increase the level of accumulations of bath residue in the whirlpool system. If excess accumulations persist, you should discontinue use of these products.

If you have followed the monthly purging instructions and still have an excess accumulation of bath residue and desire an alternative cleaning mechanism, we recommend SUPER SYSTEMS CLEAN PLUS manufactured by Stearns Packaging Corporation to rectify this condition. This may be obtained by calling Aquatic Industries, Inc., at (800) 555-5324. It is recommended that you follow the instructions provided by the manufacturer with the product. Repeated use may be necessary. SUPER SYSTEMS CLEAN PLUS does not replace the necessity to purge your whirlpool system at least twice a month with a low foaming detergent and bleach.

AQUATIC INDUSTRIES, INC.

23

Image 22
Contents Infinity Series Table of Contents Owner Information Warranty ConfirmationPurchase Registration Congratulations Read and Follow ALL Instructions Read ALL Instructions Carefully Before Installation Installation Instruction GuidelinesPRE-INSTALLATION Procedures Installation Instructions Structural PreparationStructural Preparation Leveling of the InfinityPlumbing Factory Installed Tile FlangeSee Illustration 2A Model ROUGH-IN MeasurementsFast Fill Waterfall Spout Electrical Installation Continuous Waterfall InfinityPlease see Diagrams 4A and 4B. BlowerInfinity Electronic T-HEATER Model Number HS Chromatherapy LED Lighting Infinity Series Whirlpools Infinity ON/OFF with Heater Control see Diagram 6ABathside Control Systems Infinity JET Sequencer Control see Diagram 6B Infinity AIR Bath Control see Diagram 6CInfinity AIR Bath Purge Cycle see Diagram 6C Purge 24 HoursTo Remove/Replace Pillow see Diagram 8A To adjust pressure see Diagram 7BTo replace or change jet see Diagram 7D JET OperationsTo adjust pressure see Diagram 9A To adjust pressure see Diagram 8BTo replace or change jet see Diagram 8C To replace or change jet see Diagram 9CTo adjust pressure see Diagram 11A To adjust pressure see Diagram 10ATo adjust circular pattern To replace or change jet see Diagram 11BWhirlpool User Information Electrical Installation Information Listed on pagesFCC Consumer Information Whirlpool System Cleaning Maintenance and CareInitial Cleaning AIR Bath System CleaningWater Quality Issues Surface CleaningJET Cleaning Surface Scratch RemovalWater Quality Issues Chemical QualityTreatment Troubleshooting Guide Symptoms Possible Problems Suggested SolutionsQuantity Description Color/Finish Price Replacement Parts Order FormHow To Use Please Fill OUT CompletelyReplacement Parts Order MAP Infinity SeriesAssorted Fittings Replacement Parts Order MAP 27a 27b 28a 28b 28c F I N I T Y B a T H P a R T S L I S T Assorted Fittings Aquatic Industries, Inc. Limited Lifetime Warranty IOM6 12/05