Carrier PSV manuals
Household Appliance > Heat Pump
When we buy new device such as Carrier PSV we often through away most of the documentation but the warranty.
Very often issues with Carrier PSV begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Heat Pump Carrier PSV is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Heat Pump on our side using links below.
Carrier PSV Instruction Manual
68 pages 4.84 Mb
Installation, Start-Up, and Service InstructionsCONTENTSIMPORTANT: Read the entire instruction manual before starting installation. 2 SAFETY CONSIDERATIONSGENERAL INSTALLATION Step 1 Check Jobsite 3 Step 2 Chec k Unit 5 a50-8231CODE RETURN DISCHARGE ELeft Back BRight Back SLeft Right ZRight Left Fig. 2 50PSH Dimensional Data 6 a50-8183R - Configuration Right Return / Top Discharge - Top View Fig. 3 50PSV Dimensional DataL - Configuration Left Return / Top Discharge - Top View Right Return - Air Coil Opening - Right Side View Left Return - Air Coil Opening - Left Side ViewU CODE RETURN DISCHARGE LLeft Top RRight Top 7 Fig. 4 50PSD Dimensional Dataa50-7846ef 8 Step 3 Locate Unit9 Step 4 Mount the UnitStep 5 Chec k Duct System Step 6 Install Condensate Drain 10 Step 7 Pipe Connections Step 8 Wire Field Power Supply 13 Rib Crimped Length (2 ft Length Standard)Swivel Brass Fitting Brass Fitting MPT14 Fig. 15 Units with Complete C Controller, Single-Phase15 Fig. 16 Units with Deluxe D Controller, Three-Phase (460/575 V)16 Fig. 17 Units with Complete C ECM Blower, Three-Phase (208/230 V)17 a50-8363Fig 18 Units with ECM, Complete C and LON Controller (460 V) 18 a50-8364Fig 19 Units with ECM, Deluxe D and LON Controller (460 V) 19 a50-8232Fig. 20 Units with Complete C and Premierlink Controller, Single-Phase (208/230 V) 24 a50-8380Fig. 25 WSHP Open ControlWSHP Open Inputs and Outputs Table 25 Table 4 50PSH, PSV, PSD Electrical Data PSC MotorTable 5 50PSH, PSV, PSD Electrical Data PSC High-Static Motor 26 Table 6 50PSH, PSV, PSD Electrical Data, ECM MotorCOMPLETE C CONTROL A50-7737ECM CONTROL BOARD CAPACITOR COMPRESSOR CONTACTOR TRANSFORMER Fig. 26 50PSH,PSV,PSD Typical Single-Phase Line Voltage Power Connection 27 Step 9 Wire Field Controls29 Step 10 Operate ECM Interface Board 32 PRE-START-UP System Chec kout FIELD SELECTABLE INPUTS Complete C Control Jumper Settings Deluxe D Control Jumper Settings Complete C Contr ol DIP Switches Deluxe D Contr ol DIP Switches 33 Units with Modulating Hot Water Reheat (HWR) Option 35 Deluxe D Control Accessory Relay Configura- tions START-UP Operating Limits Scr oll Compressor Rotation Unit Start-Up Cooling Mode 36 Unit Start-Up Heating ModeTable 21 50PSH, PSV, PSD009 Typical Unit Operating Pressures and Temperatures 37 Table 22 50PSH, PSV, PSD012 Typical Unit Operating Pressures and TemperaturesTable 23 50PSH, PSV, PSD018 Typical Unit Operating Pressures and Temperatures Table 24 50PSH, PSV, PSD024 Typical Unit Operating Pressures and Temperatures 38 Table 25 50PSH, PSV, PSD030 Typical Unit Operating Pressures and TemperaturesTable 26 50PSH, PSV, PSD036 Typical Unit Operating Pressures and Temperatures Table 27 50PSH, PSV, PSD042 Typical Unit Operating Pressures and Temperatures 39 Table 28 50PSH, PSV, PSD048 Typical Unit Operating Pressures and TemperaturesTable 29 50PSH, PSV, PSD060 Typical Unit Operating Pressures and Temperatures Table 30 50PSH, PSV, PSD070 Typical Unit Operating Pressures and Temperatures 40 Unit Start-Up with WSHP Open Controls41 Flow Regulati on Flushing Antifreeze 42 Cooling T ower/Boiler Systems Ground Coupled, Closed Loop and Plateframe Heat Exchanger W ell Systems OPERATION Po w e r U p M o d e Units with Aquazone Complete C Control Units with Aquazone Deluxe D Control 43 Units with HWR OptionUnits with WSHP Open Multiple Protocol 46 COMPLETE C AND DELUXE D BOARD SYSTEM TESTT est Mode 47 WSHP Open T est Mode Retry Mode Aquazone Deluxe D Control LED Indica- tors 48 SERVICEFilter s W ater Coil Condensate Drain P ans Refrigerant System Compressor Fan M o t or s Condensate Drain Cleaning Air Coil Cleaning Condenser Cleaning 49 Checkin g System Char ge Refrigerant Charging Air Coil Fan Motor Removal Replacing the WSHP Open Controllers Bat- tery TROUBLESHOOTING Contr ol Sensors Thermistor 50 WSHP Open Contr oller Thermostatic Expansion V alves 55 Moisture Check 58 APPENDIX A WSHP OPEN SCREEN CONFIGURATION60 APPENDIX A WSHP OPEN SCREEN CONFIGURATION (cont)68 HEATING CYCLE ANALYSISCOOLING CYCLE ANALYSIS97B0038N04 *Use 500 for water, 485 for antifreeze. (Btu/hr) a50-8494 a50-8495
Also you can find more Carrier manuals or manuals for other Household Appliance.