B

TECHNICAL INFORMATION

Related Standards

The Baseline Switch 2426 PWR Plus has been designed to the following standards:

Functional

IEEE 802.3 (Ethernet), IEEE 802.3u (Fast

 

Ethernet), IEEE 802.3ab and IEEE 802.3z

 

(Gigabit Ethernet), IEEE 802.3x (Flow Control),

 

IEEE 802.1D 1993 (Bridging), IEEE D802.1Q

 

1998 (Virtual LAN)

MAC

4096

Address

 

Safety

UL/CUL (UL 60950-1, CSA 22.2 No 60950-1),

 

TUV/GS (EN 60950-1), IEC 60950-1, CB

EMC Emis-

EN50081-1, EN 55022 Class A, EN50082-1,

sions

IEC 1000-4-2/3/4/6, EN60555-2 Class A, EN

 

60555-3, FCC Part 15 Subpart B Class A,

Immunity

EN 55024

Environmental

Operating Tempera- 0-45 °C (32–113 °F) ture

Storage Tempera-

-40-70 °C (-40-158 °F)

ture

 

Humidity

0-95% (non-condensing)

Standard

EN 60068 (IEC 68)—various parts

Physical

Width

44 cm (17.3 in.)

Depth

23.8 cm (9.4 in.)

Height

4.4 cm (1.7 in.) or 1U

Weight

3.2 kg (7.05 lb)

Mounting

Free standing, or 19 in. rack mounted using

 

the mounting kit supplied

Electrical

Power Inlet

IEC 320

AC Line Frequency

50/60 Hz (+/- 3 Hz)

Input Voltage

100–240 VAC (auto range)

Current Rating

3 Amp (maximum)

Maximum Power

205 W

Consumption

 

Maximum Power

154 BTU/hr

Dissipation

 

Maximum

15.4 W per port

Pover-over-Ethernet

 

Budget

 