3Com 8814, 8807, 8810 manual Connecting AC Power Cord, c CAUTION

Models: 8810 8814 8807

1 104
Download 104 pages 36.87 Kb
Page 61
Image 61
Connecting AC Power

Connecting PGND Wire and Power Cord 61

power supply has been well grounded at the power distribution room or AC power supply transformer side.

Figure 40 Ground the switch via AC PE wire

(6)

(5)

(1) (2)

(3)(4)

(1) Live line

(3) PE line

(5) Transformer

(7) Front panel of the switch

Connecting AC Power

Cord

(7)

(2) Neutral line

(4)3-core AC input cable

(6)AC power input

c CAUTION:

For lightning protection, the AC power should be led through an external lightning device into the switch.

Make sure the power switch on the PSU is at OFF position before connecting the power cord.

On the front panel of AC PSU, there is a plug-retention clamp.

Take the following steps to connect the AC power cord (coming with the switch) to the Switch 8807/Switch 8810/Switch 8814:

Step 1: Turn the clamp at the left of the PSU front panel to the right.

Step 2: Insert the plug at one end of the AC power cord into the socket on the PSU.

Step 3: Turn the clamp to the left until it grips the plug.

Step 4: Insert the other end of the power cord into an external power socket.