Manuals
/
3Com
/
Computer Equipment
/
Switch
3Com
8814, 8807, 8810 manual 3Com Switch 8800 Family, Installation Guide, Switch Switch Switch
Models:
8810
8814
8807
1
1
104
104
Download
104 pages
36.87 Kb
1
2
3
4
5
6
7
8
<
>
Troubleshooting
Specs
Install
Maintenance
Configuration
Connecting PGND Wire and Power Cord
Strap note the issues below
RESET button
ping and tracert commands
n This procedure uses a Switch 8814 work as the FTP client
Page 1
Image 1
3Com
®
Switch 8800 Family
Installation Guide
Switch 8807
Switch 8810
Switch 8814
www.3Com.com
Part No. 10015593, Rev. AB
Published: June, 2007
Page 2
Page 1
Image 1
Page 2
Contents
Installation Guide
3Com Switch 8800 Family
Switch Switch Switch
Part No. 10015593, Rev. AB Published June
UNITED STATES GOVERNMENT LEGEND
3Com Corporation 350 Campus Drive Marlborough, MA USA
ENVIRONMENTAL STATEMENT
End of Life Statement
3 INSTALLATION PREPARATION
CONTENTS
ABOUT THIS GUIDE
1 PRODUCT OVERVIEW
6 SWITCH MONITORING AND MAINTENANCE
4 SWITCH INSTALLATION
A LIGHTNING PROTECTION OF THE SWITCH
5 DEBUGGING THE SYSTEM
Conventions
ABOUT THIS GUIDE
Notice Icons
Table 2 Text Conventions
Related
Switch
Documentation
About this Document
Preface
PRODUCT OVERVIEW
Currently, the Switch 8800 Family include the following models
Preface
Figure 3 3Com Switch 8814 14-Slot Chassis
Fabric
Chassis and Slots Switch
Fabric
I/O Module
General Architecture
Switch
Functions
Switch
The following are the main functions of the backplane
Structure
AC Power System
PoE entry area
External PoE Power Rack 3C17509
MBUS Introduction
Role and function
Figure 9 Fan tray panel of the Switch 8800 Family
Fabric Modules
360 Gbps Switch Fabric
Panel
Management Ports
Compact Flash CF slot
Status LEDs
RESET button
360 Gbps Switch
Table 13 Status LEDs for the 360 Gbps Switch Fabric module
Table 11 CF status LED
Table 12 Status LEDs for I/O module
This model applies to the 3C17539. See Table 5 for its specifications
720 Gbps Switch Fabric Technical specifications
Panel
Compact Flash CF slot
Table 17 RS232/485 port specifications
Table 15 Management 10Base-T/100Base-TX port specifications
Table 18 Console port specifications
Table 16 Status LEDs for the management 10Base-T/100Base-TX port
Table 19 AUX port specifications
RESET button
Status LEDs
Table 20 CF status LED
Status LEDs
RESET button
See the section “Status LEDs” on page
supported software features
Software Features
Description
Table 24 Software features of the Switch 8800 Family
Flow control
ping and tracert commands
Table 24 Software features of the Switch 8800 Family
Description
28 CHAPTER 1 PRODUCT OVERVIEW
Table 25 I/O modules available to the Switch 8800 Family
I/O AND APPLICATION MODULES
Table 26 3C17511 module specifications
Specification
3C17512 2-port 10GBASE-X XFP Module
3C17513 12-port 1000BASE-X SFP Module
Specifications
Panel and LEDs Figure
3C17514 24-port 1000BASE-X SFP Module
Specifications
3C17516 24-port
Specifications
10/100/1000BASE-T
Module
3C17526 4-port 10GBASE-X XFP Module
Specifications
3C17527 2-port 10GBASE-X XFP Advanced Module
Specifications The 3C17527 module provide two 10GBASE-X XFP/LC ports
Panel and LEDs Figure
The 3C17526 module has two LEDs for each optical port on its panel
3C17528 48port 10/100/1000 BASE-T RJ-45 Module
Specifications
Specifications
Specifications
3C17530 24-port 1000BASE-X SFP Advanced Module
3C17531 24-port 10/100/1000BASE-T Advanced Module
3C17532 48-port 10/100/1000 BASE-T RJ-45 Access Module Specifications
Table 50 3C17533 module specifications
Specifications
Specification
3C17533 24-port 1000BASE-X SFP IPv6 Module
Specifications
Specifications
3C17534 24-port 10/100/1000BASE-T IPv6 Module
3C17536 4-port 10GBASE-X XFP QUAD IPv6 Module
Table 56 3C17537 module specifications
Table 54 3C17536 module specifications
Specification
Specification
3C17538 48-port 1000BASE-X SFP IPv6 Module
3C17542 Network Monitoring Application Module
Technical specifications
Front panel
Technical specifications
Technical specifications
Front panel
Available cables
Table 65 Technical specifications for the 3C17548
Technical specifications
Front panel
Available cables
Transceivers
Table 66 Transceiver Specifications
Front panel
Figure 32 Front panel of the 3C17548
Table 67 Switch 8800 Available Modules
Switch 8800 Port
Densities
48 CHAPTER 2 I/O AND APPLICATION MODULES
Safety
INSTALLATION PREPARATION
General Safety
Safety Recommendations against Electricity Safety Recommendations in
Strap note the issues below
Adopt electromagnetic shielding if necessary
Power Supply Requirements Space Requirements
Installation Tools
SWITCH INSTALLATION
One Switch 8807 chassis in a cabinet
Mounting the Switch in User-Supplied Cabinet
Figure 34 One Switch 8807 chassis in a cabinet Switch 8807 11U
Two Switch 8807 chassis in a cabinet
Figure 35 Two Switch 8807 chassis in a cabinet Switch880711U
One Switch 8810 chassis in a cabinet
Switch 8807 11U
Figure 36 One Switch 8810 chassis in a cabinet Switch 881014U
One Switch 8814 chassis in a cabinet
the Cabinet
Connecting PGND Wire
Connecting PGND Wire and Power Cord
Common grounding environment
Other grounding environment
Figure 38 Ground the switch when ground bar is available
c CAUTION
Connecting AC Power Cord
Figure 42 Connect AC power cord to the Switch 8810/Switch
Figure 41 Connect AC power cord to the Switch
62 CHAPTER 4 SWITCH INSTALLATION
Input LED
Grounding PoE chassis
Connecting PoE power cable
c CAUTION
Installing Fan Tray
Lightning Protection Box
Installing PoE
Installing I/O modules
Connecting console cable
Connecting Interface Cables
Introduction
Introduction
DB9/DB25 end
Introduction to RJ-45 connector
Connecting AUX cable
Connecting category-5 shielded cable
Connecting Fiber
Cable Routing Recommendations
Connecting fiber
Cable Management
Requirements
530 x 9 mm 20.9 x 0.4 in, and 580 x 13 mm 22.8 x 0.5 in
The power cords cannot be tied on the guides of any mobile components
Verifying the Installation
74 CHAPTER 4 SWITCH INSTALLATION
Switch
DEBUGGING THE SYSTEM
Setting up
Configuration
Verifying Installation before Powering the Switch
Powering and Booting the Switch
All the system LEDs on the fabrics function normal
Boot Interface The Switch 8807 is used as an example in this section
78 CHAPTER 5 DEBUGGING THE SYSTEM
Troubleshooting the PSU
SWITCH MONITORING AND 6 MAINTENANCE
The Input LED green and Output LED green are OFF
Display Power Command Indicates the PSU is Not in Position
The Fail LED red is ON Check that the
Replacing AC PSU
Hardware Maintenance
Removing an AC PSU
Removing and cleaning the air filter of PSU
Installing an AC PSU
Replacing and Cleaning the Chassis’s Air Filter
Installing the air filter of PSU
Installing the Chassis’s Air Filter
Removing and Cleaning the Chassis’s Air Filter
Required tools
Removing a Module
Figure 61 Installing a Module
Installing a Module
Replacing the Fan Tray
Required tools
Software
Upgrading the
Required cables
1 Press Ctrl+B as prompted to display the system Password prompt
To run the Xmodem application
setting the baud rate and reconnect the terminal after it is complete
8 Click Send. The Xmodem dialog box displays
TFTP and to 0x0 if you are using FTP
port using FTP
Using FTP
n This procedure uses a Switch 8814 work as the FTP client
a Load Boot ROM program
Using FTP
Software Upgrade No response from the fabric serial interface
Using TFTP
Uploading the configuration file or host program using FTP fails
The configuration did not save during the I/O module reboot
Insufficient Flash memory
Password Loss
96 CHAPTER 6 SWITCH MONITORING AND MAINTENANCE
Power
LIGHTNING PROTECTION OF THE A SWITCH
c CAUTION
Installation procedure
Installing a Lightning Arrester for the Network Port
98 CHAPTER A LIGHTNING PROTECTION OF THE SWITCH
Required tools
Installation precautions
Switch
100 CHAPTER A LIGHTNING PROTECTION OF THE SWITCH
3COM NETWORK MANAGEMENT
3Com Network Access Manager
3Com Network
Supervisor
to carry out key management and administrative tasks on midsized
Access Manager
3Com Network
Director
Network Node
HP OpenView
Manager
104 APPENDIX B 3COM NETWORK MANAGEMENT