3M 40800 Troubleshooting continued, Troubleshooting Guide, Problem, Cause, Correction

Models: 40800

1 126
Download 126 pages 4.35 Kb
Page 104
Image 104
Troubleshooting (continued)

Troubleshooting (continued)

Troubleshooting Guide

Problem

Cause

Correction

Tape is tabbing on the trailing leg on the back of the box

There is excess tension on the tape drum assembly and/or the one-way tension roller assembly

Rollers in the tape path do not rotate freely

Adjust the one-way tension roller and/or the tape drum assembly

Clean adhesive deposits from the surface, ends, and shafts of the rollers. Then lubricate roller shafts. Remove all lubricant from roller surfaces.

The blade is not cutting tape properly

The tape is threaded incorrectly

Applying mechanism spring has too little tension

Refer to tape cutting problems

Rethread the tape

Move spring hook to next tighter hole

The tape end does not stay in application position in front of the applying roller

The tape is incorrectly threaded

Flanged knurled roller overruns on return of applying mechanism to its rest position

Applying roller overruns on return of applying mechanism to its rest position

Rethread the tape

Adjust tension roller position in mounting slot to lengthen tape leg

There should be a slight drag when rotating the applying roller. If not, check friction springs and/ or friction pins and replace if necessary

The one-way tension roller is not correctly positioned

The one-way tension roller is defective

Position roller in it mounting slot so that tape end extends beyond center line of applying roller

Replace the one-way tension roller

Tape not centered on box seam

Tape drum not centered

Reposition tape drum

 

Centering guides not centered

Adjust centering guides

 

Box flaps not of equal length

Check box specifications

 

 

 