4-SPECIFICATIONS
WARNING

4-SPECIFICATIONS

1. Power Requirements:

Electrical – 120 VAC, 60 Hz, 6 A

Pneumatic – 6.5 bar gauge pressure [95 PSIG], 2.5 SCFM

75 liter/minute @ 21° C., 1.01 bar maximum at maximum cycle rate. A pressure regulator/filter is included.

The machine is equipped with two 1/6 HP gearmotors and comes with an 2.4m [8 foot] standard neoprene covered power cord and a grounded plug. Contact your 3M Representative for power requirements not listed above. Contact your 3M Representative for power requirements not listed above.

2.Operating Rate: Belt speed is 0.5m/s [100 F.P.M.]

Actual production rate is dependent on operator's dexterity. Boxes must be 18 inches (457mm) apart minimum.

3.Operating Conditions

Use in dry, relatively clean environments at 5o C to 50o C [40o F to 120o F] with clean, dry boxes.

Note: Machine should not be washed or subjected to conditions causing moisture condensation on components.

To reduce the risk associated with fire and explosion hazards:

Do not operate this equipment in potentially flammable or explosive environments.

4.Tape

Scotch® pressure-sensitive film box sealing tapes.

5.Tape Width

50mm [2 inch] minimum to 72mm [3 inch] maximum

700aks-NA

2011 October

 

12