12.2Maintaining fiber position in connector, push the jacketed fiber into the cable v-slot feature on the load adapter until secure.

12.3Attempt to line up the holder arm to keep cable as straight as possible.

12.4Remove the load adapter from the oven by grasping the cool-touch handle.

CAUTION

Do not touch the metal portion of the load adapter or connector, as it will be hot!

12.5Rest the load adapter in one of the available cooling ports located on both sides of the oven. Let cool for a minimum of 3 minutes.