CAUTION – Machine weighs approximately 114 kg [250 pounds]

Installation and Set-Up (Continued)

8.Use appropriate material handling equipment to remove the machine from the pallet and move it into position.

Whenever the machine is lifted with a fork truck, insure that the forks span completely across the machine frame and do not contact any wiring or mechanism under the machine frame. In some cases the lower taping head may need to be removed to avoid damage.

CAUTION – Machine weighs approximately 114 kg [250 pounds]

uncrated.

9.Continue with the remainder of the installation and set-up procedure on this page.

MACHINE BED HEIGHT

Adjust machine bed height. The case sealer is equipped with four adjustable legs that are located at the corners of the machine frame. The legs can be adjusted to obtain different machine bed heights from 610 mm [24 inches] minimum to 890 mm [35 inches] maximum.

Refer to Figure 2-3C and set the machine bed height as follows:

1.Raise and block up the machine frame to allow adequate leg adjustment.

2.Loosen, but do not remove, two M8 x 16 socket head screws in one leg (use M6 hex wrench). Adjust the leg length for the desired machine bed height. Retighten the two screws to secure the leg. Adjust all four legs equally.

TAPE WIDTH

The taping head has been pre-set to accommodate 48 mm [2 inch] wide tape rolls. To adjust heads for narrower tape, refer to Section II , "Adjustments – Tape Web Alignment", page 11.

TAPE LEG LENGTH

Taping heads are pre-set to apply 70 mm [2-3/4 inch] long tape legs. To change tape legs to 48 mm [2 inch], see "Special Set-Up Procedure – Changing Tape Leg Length", page 23.

ELECTRICAL CONNECTION AND CONTROLS

The electrical control box, shown in Figure 3-1, contains the pre-set circuit breaker and can be located on either side of the machine frame for customer operating convenience. A standard three conductor power cord with plug is provided at the back of the electrical control box for 115 Volt, 60 Hz, 1.9 Amp electrical service. The receptacle providing this service shall be properly grounded. Before the power cord is plugged into 115 Volt, 60 Hz outlet, make sure that all packaging materials and tools are removed from the machine. Do not plug electrical cord into outlet until ready to run machine.

Use of an extension cord is not recommended. However, if one is needed for temporary use, it must have a wire size of AWG 16 [1.5 mm dia.], have a maximum length of 30.5 m [100 ft], and must be properly grounded.

WARNING – To prevent shock and fire hazard: Position extension

cord where it will be out of the way of foot or vehicle traffic. Extension cord is only for temporary use – do not use for a permanent installation.

Note Machines outside the U.S. may be equipped with 220/240 Volt, 50 Hz systems, or other electrical requirements compatible with local practice.

INITIAL START-UP OF CASE SEALER

After completing the "Installation and Set-Up" procedure, continue through "Operation" for tape loading and start-up to be sure case sealer is properly adjusted to run boxes.