3M Dynapro ET 350 Monitor User’s Installation Guide

Step 3:Connect to power supply

Important

To reduce the risk of voiding FCC and CE compliance and reducing the performance of the ET 350 monitor, when making your own cable, reduce the sensitivity of the ET 350 monitor to electrical and radio frequency noise by connecting the cable shield to the connector shield (360º shield) on both ends of the cable.

3.Connect the other end of the serial cable to the serial port on the computer.

4.Tighten the screws of the serial cable to ensure proper connection.

The ET 350 monitor can be connected to an AC power supply in two ways: with a standard AC power cable or with fixed field wiring.

Standard AC power supply

Use an AC power cable that is appropriate for the power scheme in your country or region:

￿For applications in Europe, use a harmonized AC power cable. The universal power supply of the ET 350 monitor automatically senses the voltage from the external source and, within the range 115 to 230 VAC, 50 to 60 Hz, supplies the appropriate power without requiring any adjustment.

￿For North American applications, use a standard AC power cable.

Both types of cable are available from 3M Touch Systems and come with either an IEC connector or terminal strip wiring.

Warning

To reduce the risk of fire or electric shock which could result in serious personal injury or death:

Install the ET 350 monitor close to the power source so the unit can be easily and quickly disconnected. For permanently connected equipment, a readily accessible disconnect device must be incorporated in the fixed wiring.

Wiring installation should be done by a licensed journeyman electrician and must comply with federal and local electrical codes.

Important

Before attaching or removing communication cables, disconnect power to the ET 350.

16