3M Dynapro ET 350 Monitor User’s Installation Guide
6.Using a
7.Repeat (5) and (6) for the ground and line cable wires and then tighten the screws on the terminal block to a torque of 10 inch- pounds.
8.Fasten a cable tie around the three wires at about one inch from the terminal block (Figure 7).
Cable tie
Insulator
Cable tie (inside insulator)
Terminal block
32531
Figure 7: Terminal connection for AC power (ET 350R, ET 350L3 monitors) and for DC power
9.Make sure that one end of the insulator is flush with the terminal connector and the other end overlaps the power cable jacket by at least one inch.
10.To prevent the insulator from moving, secure the insulator to the chassis of the monitor using a cable tie or other equivalent securing device.
DC power supply (option)To connect the ET 350 Monitor to DC power supply, follow these steps:
1.Make sure that the DC power supply is disconnected at its source.
2.Strip about
3.Measure and, if necessary, cut the clear flexible insulator (supplied) so that it will cover the unjacketed portion of the power cable and overlap the jacketed portion by at least 1 inch.
4.Slide the insulator up the power cable.
5.Insert the DC- cable wire into the side connector of the terminal strip (Figure 8).
18