3M M2256PW Get Feature - GetStatus, Lower Left Calibration Target, Upper Right Calibration Target

Models: M2256PW

1 41
Download 41 pages 62.21 Kb
Page 24
Image 24
Lower Left Calibration Target

24

3M™ Multi-touch Display M2256PW User Guide

The Calibrate Extended command then positions the first calibration target inward from the lower left corner (0,1049) and the second calibration target inward from the upper right corner (1679,0). The following illustration shows how the calibration targets are calculated for a Windows-based system. Your operating system may be different.

The illustration below shows the coordinates of the calibration targets and display corners. The corners show the video coordinates in parentheses and the touch screen coordinates in brackets.

(0, 0) [0, 0]

(1679, 0) [32767, 0]

Lower Left Calibration Target

X = 0 + (1680 x 1/8) = 0 + 210 = 210 Y = 1049 - (1050 x 1/8) = 1049 - 131 = 918

(1469, 131) Upper Right Calibration Target

Get Feature - GetStatus (210, 918)

Upper Right Calibration Target

X = 1679 – (1680 x 1/8) = 1679 – 210 = 1469 Y = 0 + (1050 x 1/8) = 0 + 131 = 131

(0, 1049) [0, 32767]

(1679, 1049)

[32767, 32767]

Get Feature - GetStatus

This is a request to send information that indicates the status of the controller. Among the uses for this request are determining whether there were any power on check errors and determining whether the last request was completed successfully.

Table 5. Controller Status Setup Stage

Offset

Field

Size

Value

Description

0

bmRequestType

1

0xA1

Class,D2H,Interface

1

bRequest

1

0x01

Get Report

2

wValue

2

0x0306

msb=03=Feature

 

 

 

 

lsb=06= Feature Report ID

4

wIndex

2

0

Always 0

6

wLength

2

8

Always 8

Table 6. Controller Status Data Stage (controller response)

Offset

Field

Size

Value

Description

0

Report ID

1

0x06

Feature Report ID

1

POC Status

1

0xXX

Power On Check Status

2

Cmd Status

1

0xXX

Status of last command

3

Touch Status

1

0

Not used

4

Async Reports

1

0xXX

0x00 = async touch output off

 

 

 

 

0x01 = async touch output on

5-7

Not used

3

0

Not used

3M Touch Systems, Inc. Proprietary Information – 37531 Rev D