A.O. Smith Residential Power Vent Gas Water Heaters with Hot Surface Ignition Venting cont’d

Models: Residential Power Vent Gas Water Heaters with Hot Surface Ignition

1 40
Download 40 pages 16.21 Kb
Page 18
Image 18
40 AND 50 GALLON 40,000 BTU/HR MODELS (3″ VENT)

Installing the New Water Heater (cont’d)

Venting (cont’d)

VENTING THROUGH AN OUTSIDE WALL (cont’d)

40 AND 50 GALLON 40,000 BTU/HR MODELS (3VENT)

SEE CHART BELOW FOR MAX. LENGTH

 

 

 

4MIN.

 

 

 

 

 

 

 

 

1512MIN.

 

MIN. RISE 18

 

14MIN.

 

 

 

 

 

 

PER FIVE FEET

 

 

 

 

 

 

 

 

 

2.The total vertical and horizontal vent run cannot exceed the maximum length with the number of 90° elbows as specified in the tables below. If more elbows are required the venting distance must be reduced 5 feet for every 90˚ elbow:

75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500, 55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY

3DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

70

1

65

2

60

3

55

4

50

5

45

6

75 GALLON 70,000 and 75,000 BTU/HR, 50 GALLON 52,500,

55,000 and 62,500 BTU/HR and 40 GALLON 50,000 BTU/HR MODELS ONLY – OPTIONAL 4VENT PIPING

4DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

110

1

105

2

100

3

95

4

90

5

85

6

ALL 40 and 50 GALLON 40,000 BTU/HR MODELS ONLY

3DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

115

1

110

2

105

3

100

4

95

5

90

6

ALL 40 and 50 GALLON 40,000 BTU/HR MODELS —

OPTIONAL 2VENT PIPING

2DIA. VENT

NUMBER OF

MAX. LENGTH (FT.)

90° ELBOWS*

50

1

45

2

40

3

35

4

30

5

25

6

*NOTE: Two 45° elbows are equivalent to one 90° elbow. One 90° elbow equals 5 feet of equivalent vent length.

95’ MAX.

MIN. RISE 18

PER FIVE FEET

20’

(EXAMPLE) ONE ELBOW EXAMPLE

3″ DIA. VENT3VENT PIPE

40 GALLON

40,000 BTU/HR

MODEL EXAMPLE

3.Minimum vent length for all 40,000 BTU/HR input models is 4 feet and 16 inches for all other models.

VENTING THROUGH AN OUTSIDE WALL WITH LOW GROUND CLEARANCE

1.When the vent piping cannot pass through an outside wall at a height greater than or equal to 12above the ground (or above snow accumulation level), then the installation can be modified as shown below.

12MIN. ABOVE

GROUND OR SNOW

ACCUMULATION LEVEL

18

Page 18
Image 18
A.O. Smith Residential Power Vent Gas Water Heaters with Hot Surface Ignition Installing the New Water Heater cont’d