General Safety (cont’d)

General Safety (cont’d)

ILY INJURY, OR PROPERTY DAMAGE. WARNING

This water heater must not be installed directly on carpeting. Car- peting must be protected by a metal or wood panel beneath the appliance extending beyond the full width and depth of the ap- pliance by at least 3 inches (76.2mm) in any direction, or if the ap- pliance is installed in an alcove or closet, the entire floor must be covered by the panel. Failure to heed this warning may result in a fire hazard.

a.DO NOT cover the temperature-pressure relief valve. WARNING

A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such as a closet, unless you provide air as shown in the “Locating The New Water Heater” section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas com- pany. Failure to provide the proper amount of combustion air can result in a fire or explosion and can cause DEATH, SERIOUS BOD-

ILY INJURY, OR PROPERTY DAMAGE.

Manual background WARNING

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from out- side these areas. Refer to the “Locating The New Water Heater” section of this manual and also the current edition of the National Fuel Gas Code, ANSI Z223.1, also referred to as NFPA 54 for specifics provided concerning air required.

Manual background WARNING

The power vent water heater requires its own (separate) venting system. It cannot be connected to an existing vent pipe or chim- ney. It must be terminated to the outdoors. Failure to properly in- stall the venting system can result in asphyxiation, a fire or explo- sion and can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

Manual background WARNING

No vent damper installation is compatible with this power vented water heater design. No vent damper, whether it is operated ther- mally or otherwise is to be installed on this power vented water heater. Alteration of any part of the factory-furnished vent assembly could result in improper operation due to restriction of flue gases, spillage of flue gases and may cause carbon monoxide poisoning.

Manual background WARNING

1.The appliance and its individual shutoff valve must be discon- nected from the gas supply piping system during any pressure testing of the gas system at test pressures in excess of 12 pound per square inch (3.5kPa).

2.The appliance must be isolated from the gas supply piping sys- tem by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pres- sures equal or less than 12 pound per square inch (3.5kPa).

Manual background WARNING

Soot build-up indicates a problem that requires correction before further use. Turn “off” gas to water heater and leave “off” until re- pairs are made, because failure to correct the cause of the sooting can result in a fire or explosion causing DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.

Manual background WARNING

The water heater with vent pipe installed must be properly vented outdoors. Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation.

Manual background WARNING

Vent termination must not be within 4 feet of any items such as gas meters, gas valves or other gas regulating equipment.

Manual background WARNING

Obstructed or deteriorated vent systems may present a serious health risk or asphyxiation.

Manual background WARNING

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can pro- pellants, cleaning solvents, refrigerator and air conditioner refrig- erants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach, and process chemicals are typical compounds which are potentially corrosive.

Manual background WARNING

Minimum clearances between the water heater and combustible and non-combustible construction are: 0 inches from sides, 0 inch- es from back, 5 inches from front of jacket to closet door and 14 inches from top of jacket to combustible and non-combustible material. Minimum vent clearance: 0 inches. Provide 24 inches front clearance for servicing and adequate clearance between the jacket top & ceiling for servicing the flue area.

Manual background WARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the possibility of injury under these condi- tions, we recommend the hot water faucet be opened for several minutes at the kitchen sink before any electrical appliances which are connected to the hot water system are used (such as a dish- washer or washing machine). If hydrogen gas is present, there will probably be an unusual sound similar to air escaping through the pipe as the hot water faucet is opened. There must be no smoking or open flame near the faucet at the time it is open.

Manual background WARNING

INSULATING JACKETS: When installing an external water heater insulation jacket on a gas water heater:

a.DO NOT cover the temperature-pressure relief valve.

b.DO NOT put insulation over any part of the top of the gas water heater.

c.DO NOT put insulation over the gas control valve or gas con- trol valve/burner cover, or any access areas to the burner.

d.DO NOT let insulation around the gas water heater to get with- in 8 inches of the floor (air must get to the burner).

e.DO NOT remove operating instructions, and safety related warn- ing labels and materials affixed to the water heater. DO obtain new warning and instruction labels from the manufacturer for placement on the jacket directly over the existing labels.

Failure to heed this will result in the possibility of a fire or explosion.

Manual background WARNING

Flood damage to a water heater may not be readily visible or imme- diately detectible. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Call a qual- ified service technician or contractor to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!

Manual background CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of the water heater must be accomplished in such a manner that if the tank or any connections should leak, the flow of water will not cause dam- age to the structure. For this reason, it is not advisable to install the water heater in an attic or upper floor. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pans are available at your local hardware store. Such a drain pan must be not greater than 112 inches deep, have a mini- mum length and width of at least 2 inches greater than the water heater dimensions and must be piped to an adequate drain. The pan must not restrict combustion air flow.