![Troubleshooting (cont’d)](/images/new-backgrounds/184648/18464871x1.webp)
Troubleshooting (cont’d)
SYSTEMS CHECK
Please check guidelines below. For your safety, water heater service should be performed only by a qualified service technician.
WARNING
DO NOT
LED STATUS |
| PROBLEM |
| SOLUTION | ||
|
|
| An open earth ground circuit to the | 1. | Check that the earth ground connection is | |
▼ A | B | C | ignition system. |
| properly connected. | |
● ● ● ● ● ● |
| 2. Check that the ground conductor on the | ||||
|
|
|
|
| water heater is properly connected. | |
|
|
|
|
|
| |
▼ A | B | C | Wiring error or a high resistance to | 1. | Check for proper connection of line neutral | |
earth ground. |
| and hot wires. | ||||
● ● ● ● ● ● |
| 2. | Check that the water heater is securely | |||
|
|
|
|
| connected to earth ground. | |
|
|
|
|
|
| |
▼ A | B | C | Pressure switch remained closed longer | 1. | Pressure switch wiring is incorrect. | |
than 5 seconds after the call for heat | 2. | Replace pressure switch. | ||||
● ● ● ● ● ● | ||||||
began. |
|
| ||||
|
|
|
|
| ||
|
|
|
|
|
| |
▼ A | B | C | Pressure switch remained opened longer | 1. | Pressure switch wiring is incorrect. | |
than 5 seconds after the combustion | 2. | Pressure switch tubing not connected | ||||
● ● ● ● ● ● | blower was energized. |
| correctly. | |||
|
|
|
| 3. | Air intake or exhaust obstructed. | |
|
|
|
|
|
| |
▼ A | B | C | Error in the hot surface ignitor circuit. | 1. | Check that all wiring is correct and secure. | |
● ● ● ● ● ● |
| 2. | Replace hot surface ignitor. | |||
|
|
|
|
|
| |
|
|
| System in lockout. | 1. | Gas supply is off or too low to operate. | |
▼ A | B | C |
| 2. | Hot surface ignitor not positioned correctly. | |
| 3. | Low voltage to the water heater. | ||||
● ● ● ● ● ● |
| |||||
| 4. | Electric polarity to unit is incorrect - test | ||||
|
|
|
| |||
|
|
|
|
| and correct. | |
|
|
|
|
|
| |
▼ A | B | C | Problem in the gas valve driver circuit. | 1. | Turn power to the water heater off for | |
|
| 10 seconds and then back on. | ||||
● ● ● ● ● ● |
|
| ||||
| 2. | Replace gas control valve. | ||||
|
|
|
| |||
|
|
|
|
|
| |
▼ A | B | C | Problem with the internal circuit. | 1. | Turn power to the water heater off for | |
|
| 10 seconds and then back on. | ||||
● ● ● ● ● ● |
|
| ||||
| 2. | Replace gas control valve. | ||||
|
|
|
| |||
|
|
|
|
|
| |
▼ A | B | C | Problem with the internal circuit. | 1. | Turn power to the water heater off for | |
|
| 10 seconds and then back on. | ||||
● ● ● ● ● ● |
|
| ||||
| 2. | Replace gas control valve. | ||||
|
|
|
| |||
|
|
|
|
|
| |
▼ A | B | C | Flame signal sensed out of proper | 1. | Replace gas control valve. | |
● ● ● ● ● ● | sequence. |
|
|
▼A B C
● ● ● ● ● ● | ECO activated. | 1. | Replace gas control valve. | ||
|
|
|
|
|
|
▼ A | B | C | One of the temperature adjust buttons | 1. | Press and release each of the buttons once. |
● ● ● ● ● ● | stuck closed. | 2. | Replace gas control valve. | ||
|
|
|
|
|
|
▼ A | B | C | Water temperature sensor is either | 1. | Check that all wiring is correct and secure. |
● ● ● ● ● ● | open or short circuited. | 2. | Replace gas control valve. |