Abit NI8 SLI # Voltage Monitoring, All Voltages, Shutdown Enable, Beep Enable, High/Low Limit

Models: NI8 SLI

1 88
Download 88 pages 60.21 Kb
Page 36
Image 36
#Voltage Monitoring:

3-6

Chapter 3

 

 

#Voltage Monitoring:

Click <Enter> key to enter its submenu:

µGuru Utility V0.09

OC Guru

ABIT EQ

 

 

 

 

 

 

 

Voltage Monitoring

 

 

 

High

Low

 

 

Reading

Shutdown Beep

 

(*)CPU Core Voltage

 

1.550V

Enable

Enable

Limit

Limit

 

(*)

(*)

 

1.89V

1.00V

(*)DDR Voltage

 

2.70V

( )

(*)

 

2.90V

2.10V

(*)DDR VTT Voltage

 

1.35V

( )

(*)

 

1.55V

1.05V

(*)CPU VTT 1.2V Voltage

 

1.22V

( )

(*)

 

1.45V

0.95V

(*)NB 1.4V Voltage

 

1.45V

( )

(*)

 

1.70V

1.10V

(*)SB 1.5V Voltage

 

1.55V

( )

(*)

 

1.80V

0.20V

(*)ATX +12V(24-Pin Connector)

11.77V

( )

(*)

 

3.00V

9.60V

(*)ATX +12V(4-Pin Connector)

11.71V

( )

(*)

 

14.40V

9.60V

(*)ATX +5V

 

5.03V

( )

(*)

 

6.00V

4.00V

(*)ATX +3.3V

 

3.39V

( )

(*)

 

3.95V

2.65V

(*)ATX 5VSB

 

5.06V

( )

(*)

 

6.00V

4.00V

 

 

 

 

 

↑↓:Move Enter:Select +/-/PU/PD:Value

 

 

 

F10:Save ESC:Exit

All Voltages:

These items display the voltage of each element.

!Shutdown Enable:

Use <Space> key to enable system shutdown function. If the voltage of corresponding element is higher/lower than the high/low limit, the system would automatically shutdown.

!Beep Enable:

Use <Space> key to enable warning beeps function. If the voltage of corresponding element is higher/lower than the high/low limit, warning beeps will sound.

!High/Low Limit:

These items set the high and low voltage limit.

NOTE: The value of high limit must be set above the one of low limit.