Underwriters Laboratories Compliance Statement

Important! Before making connections, make sure you have the correct Cord Set. Check it (read the label on the cable) against the following specification list.

Operating Voltage

120 Volts

240 Volts (For North America)

240 Volts (For Europe only)

Cord Set Specifications

UL Listed/CSA Certified Cord Set

Minimum 18 AWG

Type SVT or SJT three conductor cord

Maximum length of 15 feet

Parallel blade, grounding type attachment plug rated 15A, 125V

UL Listed/CSA Certified Cord Set

Minimum 18 AWG

Type SVT or SJT three conductor cord

Maximum length of 15 feet

Tandem blade, grounding type attachment plug rated 15A, 125V

Cord Set with H05VV-F cord having three conductors with minimum diameter of 0.75 mm2

IEC-320 receptacle

Male plug rated 6A, 250V

The unit automatically matches the the connected input voltage. Therefore, no additional adjustments are necessary when connecting it to any input voltage within the range marked on the rear panel.