Table 7.4 | Other Potential Problems (Cont.) | |
|
|
|
Topic |
| Information |
|
| |
MegaRAID power | The maximum MegaRAID SCSI | |
requirements |
| and 3 A. |
|
|
|
SCSI bus |
| The ANSI specification dictates the following: |
requirements |
| The maximum signal path length between terminators is 3 meters when |
|
| using up to 4 maximum capacitance (25 pF) devices and 1.5 meters when |
|
| using more than 4 devices. |
|
| SCSI devices should be uniformly spaced between terminators, with the end |
|
| devices located as close as possible to the terminators. |
|
| The characteristic impedance of the cable should be 90 +/- 6 ohms for the |
|
| /REQ and /ACK signals and 90 +/- 10 ohms for all other signals. |
|
| The stub length (the distance from the controller's external connector to the |
|
| mainline SCSI bus) shall not exceed 0.1m (approximately 4 inches). |
|
| The spacing of devices on the mainline SCSI bus should be at least three |
|
| times the stub length. |
|
| All signal lines shall be terminated once at both ends of the bus powered |
|
| by the TERMPWR line. |
|
|
|
Windows NT |
| When Windows NT is installed using a bootable CD, the devices on the |
Installation |
| MegaRAID SCSI |
|
| Microsoft documented workaround is in SETUP.TXT. SETUP.TXT is on the CD. |
|
| To install drivers when Setup recognizes one of the supported SCSI host |
|
| adapters without making the devices attached to it available for use: |
|
| 1. Restart Windows NT Setup. |
|
| 2. Press <F6> to prevent Windows NT Setup from performing disk controller |
|
| detection when Windows NT Setup displays the following: |
|
| Setup is inspecting your computer's hardware configuration..., |
|
| This allows you to install the driver from the drivers disk you created. All |
|
| SCSI adapters must be installed manually. |
|
| 3. Press <S> to display a list of supported SCSI host adapters when Windows |
|
| NT Setup displays the following: |
|
| Setup could not determine the type of one or more mass storage devices |
|
| installed in your system, or you have chosen to manually specify an |
|
| adapter, |
|
| 4. Select Other from the bottom of the list. |
|
| 5. Insert the drivers disk you made when prompted to do so and select Mega- |
|
| RAID SCSI |
|
| In some cases, Windows NT Setup repeatedly prompts to swap disks. |
|
| Windows NT will recognize any devices attached to this adapter. |
|
| 6. Repeat this step for each host adapter not already recognized by Windows |
|
| NT Setup. |
|
|
|