Table 7.2 | BIOS Boot Error Messages (Cont.) | |||
|
|
|
|
|
Message |
| Problem | Suggested Solution | |
|
|
|
| |
1 Logical Drive | A logical drive signed on | Make sure all physical drives are properly | ||
Degraded |
| in a degraded state. | connected and are powered on. | |
|
|
| Run MegaRAID Manager to find out if any | |
|
|
| physical drives are not responding. Reconnect, | |
|
|
| replace, or rebuild any drive that is not | |
|
|
| responding. | |
|
|
|
| |
The following SCSI IDs | The physical drives with | Make sure the physical drives are properly | ||
are not responding: | SCSI IDs a, b, and c are | connected and are powered on. | ||
Channel x:a.b.c | not responding on SCSI |
|
| |
|
| channel x. |
|
|
|
|
|
|
|
|
|
|
|
|
7.3Other BIOS Error Messages
Table 7.3 describes other BIOS error messages, their meaning, and suggested solutions.
Table 7.3 | Other BIOS Error Messages |
| |
|
|
|
|
Message |
| Problem | Suggested Solution |
|
|
| |
Following SCSI disk | The physical disk roaming | Reconfigure the array. | |
not found and no | feature did not find the |
| |
empty slot available | physical disk with the |
| |
for mapping it |
| displayed SCSI ID. No slot is |
|
|
| available to map the physical |
|
|
| drive. MegaRAID cannot |
|
|
| resolve the physical drives |
|
|
| into the current configuration. |
|
|
|
| |
Following SCSI IDs | The physical drive roaming | Remove the drive or drives that should not | |
have the same data y, | feature found the same data | be used. | |
z |
| on two or more physical drive |
|
Channel x: a, b, c | on channel x with SCSI IDs a, |
| |
|
| b, and c. MegaRAID cannot |
|
|
| determine the drive that has |
|
|
| the duplicate information. |
|
|
|
|
|
Copyright © 2002 by LSI Logic Corporation. All rights reserved.