Table 7.2

BIOS Boot Error Messages (Cont.)

 

 

 

 

 

Message

 

Problem

Suggested Solution

 

 

 

 

1 Logical Drive

A logical drive signed on

Make sure all physical drives are properly

Degraded

 

in a degraded state.

connected and are powered on.

 

 

 

Run MegaRAID Manager to find out if any

 

 

 

physical drives are not responding. Reconnect,

 

 

 

replace, or rebuild any drive that is not

 

 

 

responding.

 

 

 

 

The following SCSI IDs

The physical drives with

Make sure the physical drives are properly

are not responding:

SCSI IDs a, b, and c are

connected and are powered on.

Channel x:a.b.c

not responding on SCSI

 

 

 

 

channel x.

 

 

 

 

 

 

 

 

 

 

 

 

7.3Other BIOS Error Messages

Table 7.3 describes other BIOS error messages, their meaning, and suggested solutions.

Table 7.3

Other BIOS Error Messages

 

 

 

 

 

Message

 

Problem

Suggested Solution

 

 

 

Following SCSI disk

The physical disk roaming

Reconfigure the array.

not found and no

feature did not find the

 

empty slot available

physical disk with the

 

for mapping it

 

displayed SCSI ID. No slot is

 

 

 

available to map the physical

 

 

 

drive. MegaRAID cannot

 

 

 

resolve the physical drives

 

 

 

into the current configuration.

 

 

 

 

Following SCSI IDs

The physical drive roaming

Remove the drive or drives that should not

have the same data y,

feature found the same data

be used.

z

 

on two or more physical drive

 

Channel x: a, b, c

on channel x with SCSI IDs a,

 

 

 

b, and c. MegaRAID cannot

 

 

 

determine the drive that has

 

 

 

the duplicate information.

 

 

 

 

 

7-4Troubleshooting