Appendix A
Audible Warnings
The MegaRAID SCSI
Note: This is available only if the optional series 502 Battery Backup Unit (BBU) is installed.
Table A.1 | Audible Warnings and Descriptions | ||
|
|
|
|
Tone Pattern |
| Meaning | Examples |
|
|
| |
Three seconds on | A logical drive is | One or more drives in a RAID 0 | |
and one second off | offline. | configuration failed. | |
|
|
| Two or more drives in a RAID 1, |
|
|
| or 5 configuration failed. |
|
|
| |
One second on and | A logical drive is run- | One drive in a RAID 5 configura- | |
one second off | ning in degraded | tion failed. | |
|
| mode. |
|
|
|
| |
One second on and | An automatically initi- | While you were away from the | |
three seconds off | ated rebuild has been | system, a disk drive in a RAID 1, | |
|
| completed. | or 5 configuration failed and was |
|
|
| rebuilt. |
|
|
|
|
MegaRAID SCSI |
Copyright © 2002 by LSI Logic Corporation. All rights reserved.