RANGE

Models

Operating Range

Overrange

2000P, 2020P, 2080P

25mbar / 10H2O

 

350mbar / 140H2O

2001P, 2021P, 2081P

130mbar / 52H2O

 

1bar / 401H2O

2002P, 2022P, 2082P

2bar / 28 PSI

 

4bar / 58 PSI

2003P, 2023P, 2083P

7bar / 101.5 PSI

 

10bar / 145 PSI

2024P, 2084P

External Transducer

 

-

2005P, 2025P, 2085P

2bar absolute

 

4bar

2026P, 2086P

10bar / 145 PSI

 

10.342bar / 150 PSI

 

 

 

 

 

FEATURES

 

Models

 

 

 

Features

2000P, 2001P, 2002P, 2003P, 2005P

 

Backlight, Out of Range, Zeroing,

 

Zeroing Absolute & Hold

 

 

 

2020P, 2021P, 2022P, 2023P, 2024P, 2025P, 2026P

 

As above plus: Smoothing, Units of Pressure,

 

Rangelock & Max/Min

 

 

 

 

 

 

2080P, 2081P, 2082P, 2083P, 2084P, 2085P, 2086P

 

As above plus: Manuallog and Autolog

 

 

 

 

 

Particular care should be taken not to over pressure the device as this may rupture the sensor membrane. This is not covered by the manufacturers warranty.

NOTE: The differential/gauge instruments will only measure positive pressures i.e. positive pressure applied to the positive port, or negative pressure applied to the negative port.

INSTRUMENT APPLICATION

The range of 2000P instruments are suitable for gauge, differential, or absolute measurements over a wide range of pressures. They are not suitable for use with corrosive substances or cyclic hydrocarbons, e.g. motor oil, transmission fluid and freon.

To use the 2000P with these components, isolation must be provided in the form of a buffer, such as a mineral oil or dry air.

INSTRUMENT OPERATION

BATTERIES

Two AA or equivalent cells (not supplied). Follow instructions on reverse of instrument for fitting/replacement.

When symbol appears on display, replace batteries.

IP65/IP67 RATING

The waterproof rating for this product will not be maintained unless the screws holding the battery compartment are firmly tightened when inserting or replacing batteries.

ON - OFF

Press ON key for on and OFF key for off. Automatic switch-off after 12 minutes, unless any key is activated or the instrument is in LOG

or MAX/MIN mode. If key is held when unit is switched on, automatic switch-off function will be disabled until the unit is switched off.