ADT Security Services 8112 manual Reset Sensors ? Command, Using Reset Sensors, Description

Models: 8112

1 57
Download 57 pages 3.3 Kb
Page 35
Image 35
RESET SENSORS ? COMMAND 47

RESET SENSORS ? COMMAND 47

Reset Sensors

Description

Detection devices, such as smoke detectors and shock sensors, must be reset after being activated. This function momentarily removes power from these sensors to reset them. It also clears point information from the display, leaving the ALARM SILENCED message in the display as a reminder that the View Memory function can be used to view the cleared point information. Entering a valid passcode and then pressing the ESC key clears the ALARM SILENCED message and the event memory. Arming the system will also clear the display and the event memory.

Using Reset Sensors:

1.Ensure that your command center is at idle disarmed text.

2.Press the COMMAND bar. The display shows

SYSTEM COMMAND.

3.Press the 4 key followed by the 7 key.

Note: If you prefer, you may use the Command Menu in place of steps 2 and 3 to initiate this function. Press the MENU key to enter the Command Menu, then press NEXT repeatedly until you reach the RESET SENSORS ? prompt. Press ENT.

4.The display shows SENSORS RESETING for approximately 3 seconds and then goes blank before returning to idle disarmed text.

If you enter this function and the detector or sensor resets momentarily, but then returns to a faulted condition, the conditions causing the activation may still be present or the detector may be faulty. Check to be certain that there is no smoke, fire, or other danger present.

If you can’t reset the detector or sensor contact your security company.