Document 50934 Rev B 5/15/00 PN 50934:B
30
4.0 Operating Instructions
The ADT-UDACT has five Modes of operation; Normal, Program, Lamp Test,
Troubleshoot and Type mode. Upon initial power up, the system will be in Normal
Mode. This section discusses operation of the ADT-UDACT in the Normal Mode.
4.1.1 Keys
Below is a description of the function keys in Normal Mode:
The Clear function will cause the ADT-UDACT to:
• cease transmissions
• clear any active or pending transmissions
• reset and return to normal system processing
To perform the Clear function, press the Clear Key followed by 2, 5, 3, 2, then press
the [ENTER/STORE] key.
If the Test Key is pressed three times in rapid succession the ADT-UDACT will
transmit a test message to both Central Stations. The message reported is the same as
the automatic test message for all formats except Ademco Contact ID.
Pressing the Mode Key followed by a valid 4-digit numerical code and [ENTER/
STORE] selects one of the four modes of operation.
To enter normal mode from any other mode press MODE then
6676 [ENTER/STORE]. 6676 spells NORM on a Touch-Tone® phone.
CLEAR

4.1 Normal Mode

TEST
MODE
UDACTKEY.WMF