Section 3 Engineering Guidelines | TRACER 5045 System Manual |
| ||
|
|
|
| |
|
| Table 1. Rear Panel Description1 |
| |
| Name | Connector | Description |
|
|
|
|
|
|
A | VT100 terminal (or PC with terminal emulation software) |
| ||
| connection |
| ||
|
|
|
| |
B | Test | 1/4” bantam | Factory test connection |
|
C | 10/100BaseT/TX | 10/100BaseT/TX Ethernet interfaces for LAN connections. |
| |
D | Alarm | Terminal block | External alarm monitoring system connection |
|
E | DC Power | Terminal block |
| |
F | Fuse | N/A | 2 A, 250 V, 2 inch |
|
G | Antenna | Antenna feedline cable connection |
| |
H | Ground Lug | N/A | Earth ground connection |
|
1 Detailed discussions (including pinouts) of rear panel components (where applicable) follow the table.
RS-232 Connection (DB-25) — Terminal Use
The
•Accepts
•Operates at 9600 bps
Table 2 on page 28 shows the pinout. Wiring diagrams for connecting to the
|
| Table 2. | |
|
|
|
|
PIN | NAME |
| DESCRIPTION |
|
|
|
|
1, 7 | GND |
| Ground |
|
|
|
|
2 | TX |
| Transmit |
|
|
|
|
3 | RX |
| Receive |
|
|
|
|
4 | RTS |
| Request To Send |
|
|
|
|
5 | CTS |
| Clear To Send |
|
|
|
|
6 | DSR |
| Data Set Ready (Modem Control Only) |
|
|
|
|
8 | CD |
| Carrier Detect |
|
|
|
|
— |
| Unused | |
|
|
|
|
20 | DTR |
| Data Terminal Ready (Modem Control Only) |
|
|
|
|
21 | — |
| Unused |
|
|
|
|
22 | RI |
| Ring Indicator |
|
|
|
|
— |
| Unused | |
|
|
|
|