Section 5 User Interface Guide

TRACER 5045 System Manual

 

 

>TRACER SYSTEM CONFIGURATION > SITE NAME

Provides a user-defined alphanumeric description (up to 25 characters) for the TRACER 5045 system.

>TRACER SYSTEM CONFIGURATION > MODEM CONTROL

Configures the modem control leads on the RS-232 port (terminal interface located on the rear panel of the unit). Set MODEM CONTROL to ENABLED when connecting the unit to a modem (using a null modem adapter). Setting MODEM CONTROL to DISABLED prevents the TRACER 5045 from monitoring DCD and enables data to be sent to the VT100 continuously. MODEM CONTROL must be set to DISABLED when the VT100 terminal is in use. The TRACER 5045 comes factory programmed with MODEM CONTROL set to

DISABLED.

Press <Ctrl+Z> three times from the terminal interface to disable MODEM CONTROL when the modem control leads are active.

>TRACER SYSTEM CONFIGURATION > MODEM CONNECTION (LOGOUT)

Causes the TRACER 5045 to de-assert Clear To Send (CTS) and DSR for a time greater than 20 msec. This signals the modem to disconnect the analog connection. Hangup-On-DTR-Drop may need to be explicitly enabled on some modems. If PASSWORD PROTECTION is ENABLED, this menu also causes the unit to close the current session and return to the TRACER System Status menu page and wait for password input.

>TRACER SYSTEM CONFIGURATION > PASSWORD ENABLE

Configures password protection for the VT100 terminal interface. Password protection for the TRACER 5045 requires password input from the TRACER 5045 System Status menu page when connecting to the unit. When configured for password protection, the TRACER 5045 closes any terminal session that remains inactive for more than 10 minutes. The TRACER 5045 comes factory programmed

with PASSWORD ENABLE set to DISABLED.

>TRACER SYSTEM CONFIGURATION > PASSWORD

Sets the password for password protection of the TRACER 5045 VT100 terminal interface. Enter up to 8 alphanumeric characters. The system password is case sensitive.

The default password for the TRACER 5045 is tracer.

>TRACER SYSTEM CONFIGURATION > PERFORMANCE STATS (CLEAR)

Resets all system error counters for the TRACER 5045.