ADTRAN T1-FT1 user manual # of Chan, Normal Mode of Operation

Models: T1-FT1

1 78
Download 78 pages 57.67 Kb
Page 56
Image 56

Chapter 3. Operation

# OF CHAN

Used to select the number of DS0s (channels) that are to be used. The corresponding DTE rate will be this number times 56K or 64K, depending on Port Option number 1.

Choices: 01 through 24

DATA

Used to control the inverting of the DTE data. This inversion can be useful when operating with an HDLC protocol. Often used as a means to ensure ones (1s) density. TSUs on both ends must have identical option settings.

Choices: NORMAL or INVERT

CTS

Used to control characteristics of CTS.

Choices: NORMAL, (see Table 3-1) or FORCE ON

DCD - Data Carrier Detect -

Indicates to the DTE when a valid signal is being received at the Network Interface.

Choices: NORMAL, (see Table 3-1) or FORCE ON

DSR - Data Set Ready

This signal indicates to the DTE when the DCE is turned ON and ready for operations.

Choices: NORMAL, (see Table 3-1) or FORCE ON

Table 3-1. Normal Mode of Operation

NORMAL MODE OF OPERATION

Conditions which cause the Port Control Signals to be deactivated.

SIGNAL

RTS

V-54

511 TEST

SELFT TEST

NETWK TEST

NETWORK

 

 

LOOPBK

ON

ACTIVE

ACTIVE

ALARMS

CTS

Follows

OFF

OFF

OFF

OFF

YELLOW

 

 

 

 

 

 

ALM

 

 

 

 

 

 

 

DCD

-

-

OFF

-

PATTERN

OOF

 

 

 

 

 

 

OR

 

 

 

 

 

 

AIS

 

 

 

 

 

 

 

DSR

-

OFF

OFF

OFF

OFF

-

 

 

 

 

 

 

 

Where “=” = don’t care

 

 

 

 

Force On = On under all conditions

 

 

 

3-20

TSU User Manual

61200060L1-1

Page 56
Image 56
ADTRAN T1-FT1 user manual # of Chan, Normal Mode of Operation