ADTRAN T1-FT1 user manual Data Rate, Alarms

Models: T1-FT1

1 78
Download 78 pages 57.67 Kb
Page 54
Image 54

Chapter 3. Operation

DATA RATE

Selects the data rate for the control port. This should be consistent with all units on a chain and with the modem and/or PC/Proxy Agent serial port.

Choices: 1200, 2400, 9600

2) ALARMS

Used to initialize the method by which the control port handles alarm conditions.

TRAPS

This setting determines if alarm conditions should automatically send alarm messages (traps) to the controlling PC/Proxy Agent. The setting is for this unit, or for slaves if this unit is a master.

Choices: ENAB - Enable; DISA - Disable

OUTPUT

Selects whether the alarm traps (if enabled) are sent directly, or if the telephone number stored in the TSU should be dialed first (industry-standard AT dial command sent to modem).

Choices: DIRECT or DIAL

TEL NUM

This is the telephone number which is dialed to obtain alarm traps. The string can be up to 20 characters in length and is terminated with a semi colon (;) as the last character. A colon

(:) character is used to represent a pause in the dial string.

Example: For number 9:5551212; dial 9, pause, and then send 5551212. This pause could be effected to access an outside line form a PBX, etc.

When editing a specific character, the scroll keys are used to scroll from 0 to 9, then “:” and “;”. The new telephone number is entered into the TSU only upon pressing ENTER after typing the “;”.

Choices: 20 digits (0-9, : and ;)

The typed digits are accepted only after pressing ENTER.

3-18

TSU User Manual

61200060L1-1

Page 54
Image 54
ADTRAN T1-FT1 user manual Data Rate, Alarms