6PCI-1710 /1710HG User's Manual
Analog Output:
Channels: 2
Resolution: 12-bit
Relative accuracy: ±1/2 LSB
Gain error: ±1 LSB
Maximum update rate: 100 K samples/s
Slew rate: 10 V/µs
Output range: (software programmable)
With internal reference: 0 ~ +5 V, 0 ~ +10 V
With external reference: 0 ~ +x V @ -x V (-10 x 10)
Digital Input:
Channels: 16
Input voltage:
Low: 0.4 V max.
High: 2.4 V min.
Input load:
Low: -0.2 mA @ 0.4 V
High: 20 µA @ 2.7 V
Digital Output:
Channels: 16
Output voltage:
Low: 0.4 V max. @ 8.0 mA (sink)
High: 2.4 V min. @ -0.4 mA (source)