4.13Digital I/O Registers — BASE+16 and BASE+17
The
Table
Read |
|
|
| Digital Input |
|
|
| |
|
|
|
|
|
|
|
|
|
Bit # | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|
|
|
|
|
|
|
|
|
BASE+17 | DI15 | DI14 | DI13 | DI12 | DI11 | DI10 | DI9 | DI8 |
|
|
|
|
|
|
|
|
|
BASE+16 | DI7 | DI6 | DI5 | DI4 | DI3 | DI2 | DI1 | DI0 |
|
|
|
|
|
|
|
|
|
Table |
|
|
| |||||
|
|
|
|
|
|
|
| |
Write |
|
|
| Digital Output |
|
|
| |
|
|
|
|
|
|
|
|
|
Bit # | 7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
|
|
|
|
|
|
|
|
|
BASE+17 | DO15 | DO14 | DO13 | DO12 | DO11 | DO10 | DO9 | DO8 |
|
|
|
|
|
|
|
|
|
BASE+16 | DO7 | DO6 | DO5 | DO4 | DO3 | DO2 | DO1 | DO0 |
|
|
|
|
|
|
|
|
|
Note! The default configuration of the digital output chan- nels is a logic 0. This avoids damaging external devices during system
4.14Programmable Timer/Counter Registers — BASE+24, BASE+26, BASE+28 and BASE+30
The four registers of BASE+24, BASE+26, BASE+28 and BASE+30 are used for the 82C54 programmable timer/counter. Please refer to Appendix A data sheets for detailed application information.
Note! Users have to use a
44