SPECIFICATIONS
Model | Height x Width x Depth | Gas Connection | NAT / LP | Weight | ||
Installed | Shipped | |||||
|
|
|
| |||
TMFG18 | 25.625” x 12” x 25” | 3/8” NPT | 24,000 BTU/HR | 64 lbs | 73 lbs | |
62.6cm x 30.5cm x 61cm | 1cm NPT | 29 kg | 33.1 kg | |||
|
| |||||
TMFG30 | 23.375” x 24” x 25.125” | 1/2” NPT Female | NAT:70,000 BTU/HR | 110 lbs | 118 lbs | |
59cm x 61cm x 64cm | 2cm NPT Female | LP:65,000 BTU/HR | 50 kg | 54 kg | ||
|
| GENERAL INSTALLATION DATA |
| PLACE THE LAMINATED WARNING SIGN SUPPLIED WITH THE FRYER IN AN AREA |
CAUTION | VISIBLE TO THE FRYER OPERATOR. |
| This equipment is designed and sold for commercial use only by personnel trained and |
| experienced in its operation and is not sold for consumer use in and around the home nor for use |
| directly by the general public in food service locations. |
Before using your new equipment, read and understand all the instructions & labels associated with the unit prior to putting it into operation. Make sure all people associated with its use understand the units operation & safety before they use the unit.
All shipping containers should be checked for freight damage both visible and concealed. This unit has been tested and carefully packaged to insure delivery of your unit in perfect condition. If equipment is received in damaged condition, either apparent or concealed, a claim must be made with the delivering carrier.
Concealed damage or loss - if damage or loss is not apparent until after equipment is unpacked, a request for inspection of concealed damage must be made with carrier within 15 days. Be certain to retain all contents plus external and internal packaging materials for inspection. The
carrier will make an inspection and will supply necessary claim forms.
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE "ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing the equipment.
This appliance and control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 PSIG (1.034 ATM). This appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG (1.034 ATM). For your protection, we recommend a qualified installing agency install this appliance. They should be familiar with gas installations and your local gas requirements. In any case, your gas company should be called to approve the final installation. In addition, there should be posted, in a prominent location, detailed instructions to be followed in the event the operator smells gas. Obtain the instructions from the local gas supplier.
FRYERSHOULDBERESTRAINEDTOPREVENTTIPPINGWHENINSTALLEDTO AVOID SPLASHING OF HOT LIQUID. USEADEQUATE TIES WHEN INSTALLING