Regency L900-NG Maintenance, Control Module Replacement, Heat Shield Latch Location Latch, Hinge

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 45
Image 45
CONTROL MODULE REPLACEMENT

MAINTENANCE

CONTROL MODULE REPLACEMENT

1) Remove the exterior brick panels.

3) Loosen the 2 screws that hold the left side

7) Disconnect the 3 connectors from the

 

heat shield in place.

control module.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Heat

Shield

Latch Location

Latch

8)Pull out the control module.

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

4)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

NOTE: The control module is held in place with velcro.

Hinge

Heat

Shield

Door

 

9) Replace the control module

5)Unplug the power source.

10) Reverse steps to re-install.

6)Cut the cable tie that is holds the wires connected to the control module.

MAINTENANCE

c. Place the door on a soft surface to prevent scratching.

Control Module

Regency® L900 Direct Vent Gas Fireplace

45

Page 45
Image 45
Regency L900-NG, L900-LP Maintenance, Control Module Replacement, Heat Shield Latch Location Latch, Bracket, Hinge, Door