Regency L900-NG, L900-LP Installation, Pilot Shield, Heat Shield, using a flat head screw driver

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 29
Image 29
Pilot

INSTALLATION

6) Replace the front burner orifice with orifice

10) Remove the NG pilot orifice with the Allen

14) Disconnect the 2 grey connectors from

#56. See image below. Use another wrench

Key and replace with LP pilot orifice.

the modulator coil.

to hold onto the elbow behind the orifice.

 

 

7)Replace the back burner orifice with orifice #50. See image below. Use another wrench to hold onto the elbow behind the orifice.

Front Burner

Rear Burner

Orifi ce

Orifi ce

11)Re-install the pilot head and pilot shield.

12) Loosen the 2 screws that hold the right

15) Remove the right side panel by undoing the

9 screws.

side heat shield.

 

INSTALLATION

8)Remove the pilot shield by removing the 2 screws.

Pilot

Shield

Heat

Shield

13)Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket (located directly above the heat shield).

16)Using a Torx T20, remove and discard the 3 pressure regulator mounting screws. Remove the modulator coil and the gasket.

9)Remove the clip from the pilot head assembly

using a flat head screw driver.

Bracket

Clip

Heat

Shield

Regency® L900 Direct Vent Gas Fireplace

29

Page 29
Image 29