Regency L900-NG Installation, Framing & Finishing, Header On Edge, 2108mm, 673mm, 1321mm, Diagram

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 11
Image 11
FRAMING & FINISHING

INSTALLATION

FRAMING & FINISHING

1)Frame in the enclosure for the unit with framing material. The framed opening for the assembled kit is 50-3/4" high x 52" wide x 26-1/2" deep (1289mm x H 1321mm W x 673mm D). See Diagram 1. Also see Diagram 2 for corner installations.

Header

(On Edge) Header

 

83"

3/4"-50 (1289mm)

(2108mm)
Min. 26-1/2"

 

(673mm)

52”

 

(1321mm)

 

Diagram 1

 

Drywall

Header

 

(On Edge)

1/2-17 (445mm)”

Non-Combustible

Material

5”

(127mm)

2”

(51mm)

(311mm)”1/4 -12

6”

(152mm)

(1930mm)76”

26-1/2”

(673mm)

Diagram 3

INSTALLATION

Diagram 2

Non-Combustible Requirements

 

 

53-3/4"

 

Stud

 

 

 

(1365mm)

 

 

17-7/16"

(443mm)

Non-combustible

 

 

Material

 

 

 

 

 

 

 

 

33-1/8"

 

52-1/2"

(1334mm)

35-1/16”

(891mm)

(838mm)

 

32-1/16”

(814mm)

 

 

10-5/16"

 

3"

 

 

 

(254mm)

 

 

 

 

 

(76mm)

 

 

 

 

Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed. See diagram 3 for details.

2)For exterior walls, insulate the enclosure to the same degree as the rest of the house, apply vapour barrier and drywall, as per local installation codes. (Do not insulate the fireplace itself.)

3)The unit does not have to be completely enclosed in a chase. You must maintain clearances from the vent to combustible materials: See "Clearances" section. Combustible materials can be laid against the side and back standoffs and the stove base.

IMPORTANT

If converting this unit to LP, it is highly recommened the conversion be done BEFORE the unit is slid into position for ease of conversion. See "Conversion from NG to LP" section for instructions.

Regency® L900 Direct Vent Gas Fireplace

11

Page 11
Image 11
Regency L900-NG Installation, Framing & Finishing, Header On Edge, 2108mm, 673mm, 1321mm, Min. 26-1/2, Non-combustible