Regency L900-LP, L900-NG Installation, Horizontal Venting with Two 2 90o Elbows, Option, H + H1

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 20
Image 20
Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

Horizontal Venting with Two (2) 90o Elbows

INSTALLATION

One 90o elbow = Two 45o elbows.

Option

 

V

H + H1

With these

options,

A)

3'

Min.

2' Max.

maximum total pipe length

B)

4'

Min.

4' Max.

is 30 feet with minimum of

C)

6'

Min.

8' Max.

10 feet total vertical and

 

 

 

 

maximum 10

feet total

D)

8'

Min.

9' Max.

 

 

 

 

horizontal.

 

E)

10' Min.

10' Max.

 

 

 

Please note minimum 1 foot between 90o elbows is required.

VENT RESTRICTOR SETTING:

Vent restrictor at 0" - factory set, no adjustment required.

Horizontal Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option V

H

V + V1 H + H1

A)2' Min. 1' Max. 5' Min. 2' Max.

B)3' Min. 1' Max. 6' Min. 3' Max.

C)4' Min. 3' Max. 8' Min. 6' Max.

D)5' Min. 4 Max. 10' Min. 8' Max.

E)5' Min. 4' Max. 11' Min. 10' Max.

VENT RESTRICTOR SETTING:

Vent restrictor at 0" - factory set, no adjustment required.

With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 10 feet total horizontal.

Please note min. 1 foot between 90o

20

Regency® L900 Direct Vent Gas Fireplace

Page 20
Image 20
Regency L900-LP Installation, Horizontal Venting with Two 2 90o Elbows, Horizontal Venting with Three 3 90o Elbows, Option