Regency L900-NG, L900-LP Installation, Vertical Venting with Three 3 90o Elbows, Option, H + H1

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 21
Image 21
Vertical Venting with Three (3) 90o Elbows

Vertical Venting with Three (3) 90o Elbows

One 90o elbow = Two 45o elbows.

Option

V

H + H1

V + V1

With these options, max.

A)

2' Min.

3' Max.

4' Min.

 

 

 

 

total pipe length is 30 feet

B)

3' Min.

4' Max.

6' Min.

with min. of 10 feet total

C)

4' Min.

5' Max.

8' Min.

vertical and max. 8 feet

D)

5' Min.

6' Max.

9' Min.

total horizontal.

E)

6' Min.

8' Max.

10' Min.

Please note min. 1 foot

 

 

 

 

VENT RESTRICTOR SETTING:

between 90o elbows is

Vent restrictor at 0" - factory set, no

required.

adjustment required.

 

 