Regency L900-NG Maintenance, Valve Tray Replacement, Latch Location Latch, Heat Shield, Bracket

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 47
Image 47
VALVE TRAY REPLACEMENT

MAINTENANCE

VALVE TRAY REPLACEMENT

1)Remove the exterior brick panels.

2)Remove the glass door.

a.Release the 2 door latches on the left and right side at the top of the fi rebox.

Latch Location

Latch

3)Loosen the 2 screws that hold the left side heat shield in place.

Heat

Shield

4)Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket (located directly above the heat shield).

Bracket

9)Remove the front burner by removing the screw.

Front Burner

Front Burner Removed

b.Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up.

Heat

Shield

Hinge

Door

5) Unplug the power source.

6) Remove the log set.

7) Remove the interior brick panels.

8) Remove the grate by undoing the 2 screws on the right and left side.

c.Place the door on a soft surface to prevent scratching.

10)Remove the back burner by removing the screw.

Back Burner

11)Remove the rear log stand by removing the 4 screws.

MAINTENANCE

Rear Log Stand

Grate