Regency L900-LP Installation, Installer Notice, This instructions must be left with the appliance

Models: L900-LP L900-NG

1 56
Download 56 pages 54.9 Kb
Page 30
Image 30
NOTE: Once the unit has been installed;

INSTALLATION

INSTALLATION

17)Ensure that the new rubber gasket (supplied with coil) is properly positioned and install the new modulating pressure regulator as- sembly to the valve using the screws sup- plied with the kit. Tighten screws securely.

18)Install the enclosed identification label to the valve body where it can be easily seen.

19)Attach the LP conversion decal near or on top of the serial no. decal.

20)Replace yellow "Natural Gas" label with red "Propane" label.

21)Re-install the right side panel and all electrical connections to the valve. (2 grey wires to modulating coil.)

22)Remove the left side panel by undoing the 8 screws.

23)Locate the control box shown below and remove the J9 jumper using needle nose pliers.

J9 Jumper Location

J9 Jumper

24)Re-install the left side panel.

25)Re-install the rear log support bracket.

26)Adjust the burner aeration settings to the LP settings and install the burners.

Front Burner

1/4"

Rear Burner

3/8"

27)Re-install the grate.

28)Re-install the glass door.

29)Re-install the right heat shield.

30)Continue with completing unit installation.

NOTE: Once the unit has been installed;

a)Turn on the gas supply and check for gas leaks.

b)Check the inlet and outlet pressures.

c)Check operation of flame control using the remote control. Refer to FireWizard operation manual for details.

d)Check for proper flame appearance.

Installer Notice:

This instructions must be left with the appliance.

30

Regency® L900 Direct Vent Gas Fireplace

Page 30
Image 30