Read all instructions before installing or using this appliance.
Installation Instructions
Save these instructions for future reference.
Secure the squeeze connector in place in the
bracket by tightening the squeeze connector
screws.
Refit the electrical connection cover.
Fitting a 3-Wire Power Cord
Disconnect the supplied power cord from the
terminal block and ground post. Keep the terminal
block parts; you will need them. Remove the strain
relief clamp from the power cord and remove
the power cord and strain relief clamp from the
mounting bracket. Discard the strain relief clamp.
NOTE: Do not install the power cord without a
strain relief - use the clamp supplied with the
cord.
Fit the new strain relief device to the mounting
bracket by removing the two clamping screws,
feeding the two halves (ears first) through the hole
in the mounting bracket and loosely refitting the
screws. Insert the power cord through the strain
relief device but do not tighten the device yet.
A Ground strap is supplied in the conversion pack.
ground strap.
Fit the Ground strap to the ground and center
terminal of the connector block - see the figure.
The neutral or ground wire of the power cord must
be connected to the neutral terminal located in
the center of the connector block. The power leads
must be connected to the outside terminals.
Make sure the connections are tight. Now tighten
the stain relief device to clamp the power cord.
Refit the electrical connection cover
3-Wire Conduit InstallationDisconnect the supplied power cord from the
terminal block and ground post. Keep the terminal
block parts; you will need them. Remove the strain
relief clamp from the power cord and remove
the power cord and strain relief clamp from the
mounting bracket.
The range is shipped with reducer plates to give a 1
1/8’’ diameter opening for conduit connection. Find
the reducer plates in the conversion kit and fit them
to the mounting bracket.