Notices

© Agilent Technologies, Inc. 2005

No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or transla- tion into a foreign language) without prior agreement and written consent from Agi- lent Technologies, Inc. as governed by United States and international copyright laws.

Acknowledgments

UNIX® is a registered trademark of the Open Group.

Windows NT® is a U.S. registered trade- mark of Microsoft Corporation.

Windows® and MS Windows are U.S. reg- istered trademarks of Microsoft Corpora- tion.

Manual Part Number

85225-90023

Edition

First edition, April 2005

Printed in USA

Agilent Technologies, Inc.

1400 Fountaingrove Parkway

Santa Rosa, CA 95403 USA

Warranty

The material contained in this docu- ment is provided “as is,” and is sub- ject to being changed, without notice, in future editions. Further, to the max- imum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a par- ticular purpose. Agilent shall not be liable for errors or for incidental or consequential damages in connection with the furnishing, use, or perfor- mance of this document or of any information contained herein. Should Agilent and the user have a separate written agreement with warranty terms covering the material in this document that conflict with these terms, the warranty terms in the sep- arate agreement shall control.

Technology Licenses

The hardware and/or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license.

Restricted Rights Legend

If software is for use in the performance of a U.S. Government prime contract or sub- contract, Software is delivered and licensed as “Commercial computer soft- ware” as defined in DFAR 252.227-7014 (June 1995), or as a “commercial item” as defined in FAR 2.101(a) or as “Restricted computer software” as defined in FAR 52.227-19 (June 1987) or any equivalent

agency regulation or contract clause. Use, duplication or disclosure of Software is subject to Agilent Technologies’ standard commercial license terms, and non-DOD Departments and Agencies of the U.S. Gov- ernment will receive no greater than Restricted Rights as defined in FAR

52.227-19(c)(1-2) (June 1987). U.S. Govern- ment users will receive no greater than Limited Rights as defined in FAR 52.227-14 (June 1987) or DFAR 252.227-7015 (b)(2) (November 1995), as applicable in any technical data.

Page 2
Image 2
Agilent Technologies 85225F manual Manual Part Number

85225F specifications

Agilent Technologies 85225F is a high-performance microwave signal generator designed for the most demanding test and measurement applications in the RF and microwave frequency domains. This versatile instrument is a vital tool for engineers and technicians who require precise and reliable signal generation in various fields such as telecommunications, aerospace, and electronic warfare.

One of the main features of the Agilent 85225F is its frequency coverage, which spans from 0.1 to 26.5 GHz. This broad frequency range allows users to address a wide array of applications, including component testing, system verification, and radar signal simulation. With exceptional frequency resolution and accuracy, the 85225F ensures the generation of clean and stable signals tailored to specific operational requirements.

The 85225F incorporates advanced phase-locked loop (PLL) technology, which contributes to its superior frequency stability and low phase noise. This technology is crucial for applications requiring precise signal integrity and minimal jitter, such as digital communications and high-frequency circuit testing. The instrument’s low phase noise is particularly advantageous for sensitive measurements and data transmission systems where signal quality is paramount.

In addition to its impressive frequency and phase noise characteristics, the Agilent 85225F features multiple modulation capabilities, including amplitude modulation (AM), frequency modulation (FM), and pulse modulation. These modulation options enable users to simulate a wide variety of real-world signals and testing conditions, enhancing the versatility of the instrument in various testing environments.

The 85225F also offers a user-friendly interface that facilitates ease of operation. The clear LCD screen displays essential parameters and settings, allowing users to make adjustments quickly and efficiently. Furthermore, the instrument supports remote programming and automation through its GPIB or LAN connectivity options, making it suitable for integration into larger test systems.

Another notable characteristic of the Agilent 85225F is its compact design, which does not compromise on performance. This space-saving design makes it ideal for both lab and field applications, allowing engineers to transport the generator with ease, while still maintaining the ruggedness required for demanding environments.

Overall, the Agilent Technologies 85225F stands out as a robust and reliable microwave signal generator, equipped with state-of-the-art features and technologies that cater to the needs of modern RF testing. Its broad frequency coverage, advanced modulation capabilities, low phase noise, and user-friendly interface make it an essential tool for a wide range of applications in the RF and microwave sector.