safety standards of design, manufacture, and intended use of the product. Agilent Technologies, Inc. assumes no liability for the customer’s failure to comply with these requirements.

For additional safety precautions, including precautions for making device measurements in a floating ground configuration, see “To ensure your safety while using the system" on page 76.

WA R N I N G

This is a Safety Class 1 Product (provided with a protective earthing

ground incorporated in the mains supply cord). The mains plug shall

 

 

be inserted only in a socket outlet provided with a protective earth

 

contact. Any interruption of the protective conductor inside or

 

outside of the product is likely to make the product dangerous.

 

Intentional interruption is prohibited.

 

 

 

If this product is not used as specified, the protection provided by the

WARNING

equipment could be impaired. This product must be used only in a

 

 

normal condition (in which all means for protection are intact) only.

 

 

 

DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE. Do not operate

WARNING

the instrument in the presence of flammable gases or flames.

 

 

 

 

DO NOT REMOVE THE INSTRUMENT COVER. Operating personnel

WARNING

must not remove instrument covers. Component replacement and

 

 

internal adjustments must be made only by qualified service

 

personnel. Instruments that appear damaged or defective should be

 

made inoperative and secured against unintended operation until

 

they can be repaired by qualified service personnel.

 

 

 

Installing additional instruments may destabilize the rack cabinet.

WARNING

 

 

 

 

Installing additional instruments into the cabinet electrical system

WARNING

could produce excessive leakage current. If the protective earth

 

 

conductor is interrupted or faulted, the user risks serious injury or

 

death.

 

 

 

Prior to adding any additional instruments, review all wiring and

WARNING

cooling capabilities to verify adequate design margins for normal and

 

 

under single fault conditions.

 

 

6

Installation and User’s Guide

Page 6
Image 6
Agilent Technologies 85225F manual Do not Operate in AN Explosive ATMOSPHERE. Do not operate

85225F specifications

Agilent Technologies 85225F is a high-performance microwave signal generator designed for the most demanding test and measurement applications in the RF and microwave frequency domains. This versatile instrument is a vital tool for engineers and technicians who require precise and reliable signal generation in various fields such as telecommunications, aerospace, and electronic warfare.

One of the main features of the Agilent 85225F is its frequency coverage, which spans from 0.1 to 26.5 GHz. This broad frequency range allows users to address a wide array of applications, including component testing, system verification, and radar signal simulation. With exceptional frequency resolution and accuracy, the 85225F ensures the generation of clean and stable signals tailored to specific operational requirements.

The 85225F incorporates advanced phase-locked loop (PLL) technology, which contributes to its superior frequency stability and low phase noise. This technology is crucial for applications requiring precise signal integrity and minimal jitter, such as digital communications and high-frequency circuit testing. The instrument’s low phase noise is particularly advantageous for sensitive measurements and data transmission systems where signal quality is paramount.

In addition to its impressive frequency and phase noise characteristics, the Agilent 85225F features multiple modulation capabilities, including amplitude modulation (AM), frequency modulation (FM), and pulse modulation. These modulation options enable users to simulate a wide variety of real-world signals and testing conditions, enhancing the versatility of the instrument in various testing environments.

The 85225F also offers a user-friendly interface that facilitates ease of operation. The clear LCD screen displays essential parameters and settings, allowing users to make adjustments quickly and efficiently. Furthermore, the instrument supports remote programming and automation through its GPIB or LAN connectivity options, making it suitable for integration into larger test systems.

Another notable characteristic of the Agilent 85225F is its compact design, which does not compromise on performance. This space-saving design makes it ideal for both lab and field applications, allowing engineers to transport the generator with ease, while still maintaining the ruggedness required for demanding environments.

Overall, the Agilent Technologies 85225F stands out as a robust and reliable microwave signal generator, equipped with state-of-the-art features and technologies that cater to the needs of modern RF testing. Its broad frequency coverage, advanced modulation capabilities, low phase noise, and user-friendly interface make it an essential tool for a wide range of applications in the RF and microwave sector.