Verifying System Functionality

3

To perform the system functional verification test (continued)

Step

Action

Notes

 

 

 

7 Open the attenuator test

a From the IC-CAP/Main window menu bar,

This opens the File Open dialog box.

model in IC-CAP.

choose File > Examples... .

 

 

b In the Directories list of the File Open dialog

This opens a list of model files.

 

box, double-click on the directory

 

 

.../examples/model_files.

 

cIn the Directories list of the File Open dialog box, double-click on the directory

.../model_files/misc.

dIn the Files list of the File Open dialog, double-click on sys_testrf.mdl.

(Scroll the list, if needed.) This displays a list of modeling files in the Files list of the File Open dialog.

This opens the Atten model window.

The Atten model window contains tab folders used to interact with the model data.

8Set the model variables for the measurement in IC-CAP.

aClick the Model Variables tab folder.

bHighlight the freq_start variable and enter

4.5E+07.

cHighlight the freq_stop variable and enter

50E+09.

dHighlight the imax variable and enter 90m.

This opens the Model Variables tab folder.

This sets the start frequency of the model to 45 MHz.

This sets the stop frequency of the model to 50 GHz.

This sets the maximum current to 90 milliamps.

9Set the network analyzer instrument options for the attenuator test model in IC-CAP.

aIn the DUTs-Setups tab folder, click

S_vs_freq in the Select DUT/Setup list.

bClick the Instrument Options tab folder.

cHighlight the Cal Type value and enter H.

dHighlight the Cal File Name value and enter

TEST.CST.

This opens the 5 tab folders used for the S_vs_freq setup.

This opens the Instrument Options tab folder.

Adjustable instrument parameters are listed in group boxes titled as instrument model number.bus address. instrument address (for example, AgilentPNA.7.16 for the network analyzer group box).

Terminate your value entries by pressing Enter on the controller keyboard.

Installation and User’s Guide

97

Page 97
Image 97
Agilent Technologies 85225F manual Choose File Examples, Examples/modelfiles, Modelfiles/misc

85225F specifications

Agilent Technologies 85225F is a high-performance microwave signal generator designed for the most demanding test and measurement applications in the RF and microwave frequency domains. This versatile instrument is a vital tool for engineers and technicians who require precise and reliable signal generation in various fields such as telecommunications, aerospace, and electronic warfare.

One of the main features of the Agilent 85225F is its frequency coverage, which spans from 0.1 to 26.5 GHz. This broad frequency range allows users to address a wide array of applications, including component testing, system verification, and radar signal simulation. With exceptional frequency resolution and accuracy, the 85225F ensures the generation of clean and stable signals tailored to specific operational requirements.

The 85225F incorporates advanced phase-locked loop (PLL) technology, which contributes to its superior frequency stability and low phase noise. This technology is crucial for applications requiring precise signal integrity and minimal jitter, such as digital communications and high-frequency circuit testing. The instrument’s low phase noise is particularly advantageous for sensitive measurements and data transmission systems where signal quality is paramount.

In addition to its impressive frequency and phase noise characteristics, the Agilent 85225F features multiple modulation capabilities, including amplitude modulation (AM), frequency modulation (FM), and pulse modulation. These modulation options enable users to simulate a wide variety of real-world signals and testing conditions, enhancing the versatility of the instrument in various testing environments.

The 85225F also offers a user-friendly interface that facilitates ease of operation. The clear LCD screen displays essential parameters and settings, allowing users to make adjustments quickly and efficiently. Furthermore, the instrument supports remote programming and automation through its GPIB or LAN connectivity options, making it suitable for integration into larger test systems.

Another notable characteristic of the Agilent 85225F is its compact design, which does not compromise on performance. This space-saving design makes it ideal for both lab and field applications, allowing engineers to transport the generator with ease, while still maintaining the ruggedness required for demanding environments.

Overall, the Agilent Technologies 85225F stands out as a robust and reliable microwave signal generator, equipped with state-of-the-art features and technologies that cater to the needs of modern RF testing. Its broad frequency coverage, advanced modulation capabilities, low phase noise, and user-friendly interface make it an essential tool for a wide range of applications in the RF and microwave sector.