Language Dictionary    71
Table 7-3.  Agilent SAS Programming Parameters (in Fixed Mode)
Parameter Agilent E4350B Agilent E4351B
CURR[:LEV] MAX and 8.16 A 4.08 A
CURR[:LEV]:TRIG MAX 8.16 A 4.08 A
CURR:PROT[:LEV]: MAX 10 A 5 A
(Programming range is 0 to MAX)
*RST Current Value 0.096 A 0.048 A
*RST Current Protect Value MAX for both models
OUTP:PROT:DEL
*RST Value 0 to 32.767 s (MAX) both models
200 ms both models
VOLT[:LEV] MAX and 61.50 V 123.0 V
VOLT[:LEV]:TRIG MAX 61.50 V 123.0 V
(Programming range is 0 to MAX)
*RST Voltage Value 0 V for both models
VOLT:PROT MAX 73.0 V 140.0 V
(Programming range is 0 to MAX)
*RST OVP value 73.0 V 140.0 V
 See appendix B.
 This subsystem controls the state and output of the alphanumeric portion of the display.
 DISP
 Enables or disa bles the display.  When disabled, the display characters are blank.  T he annunciators are not affected by this
command.
 Command Syntax DISPlay[:WINDow][:STATe] <bool>
 Parameters  0 | 1 | OFF | ON
 *RST Value ON
 Examples DISP ON     DISPLAY:STATE ON
 Query Syntax DISPlay[:WINDow][STATe]?
 Returned Parameters <NR1> 0 or 1
 Related Commands DISP:MODE    DISP:TEXT    *RST
 DISP:MODE
 Switches the display between its normal metering mode and a mode in which it displays text sent by the user.
 Command Syntax DISPlay[:WINDow]:MODE <CRD>
 Parameters NORMal | TEXT
 *RST Value NORM
 Examples DISP:MODE NORM      DISPLAY:MODE NORMAL
 Query Syntax DISPlay[:WINDow]:MO DE?
 Returned Parameters <CRD>   NORMAL or TEXT
 Related Commands DISP    DISP:TEXT    *RST