Specifications for Frequency and Power Characteristics
Frequency | Frequency range |
Option 1
501250 kHz to 1 GHz
502250 kHz to 2 GHz
503250 kHz to 3 GHz
504250 kHz to 4 GHz
506 | 250 kHz to 6 GHz [requires Option UNJ] |
|
| ||||
|
|
|
|
|
|
| |
Frequency minimum | 100 kHz 2 |
|
|
|
| ||
Frequency resolution | 0.01 Hz |
|
|
|
| ||
|
|
|
|
|
| ||
Frequency switching speed 3 |
|
|
|
| |||
|
| Option | With Option UNJ | Option 506 | |||
|
| Freq.4 | Freq./Amp.5 | Freq.4 | Freq./Amp.5 | Freq.4 Freq./Amp.5 | |
| Digital modulation |
|
|
|
|
| |
| on | (< 35 ms) (< 49 ms) | (< 35 ms) (< 52 ms) | (< 41 ms) (< 57 ms) | |||
| off | (< 9 ms) | (< 9 ms) | (< 9 ms | (< 9 ms) | (< 16 ms (< 17 ms) | |
| [For hops < 5 MHz within a band] |
|
|
|
| ||
| Digital modulation |
|
|
|
|
| |
| on | (< 9 ms) | (< 9 ms) | (< 9 ms) | (< 9 ms) | (< 33 ms) (< 53 ms) | |
| off | (< 9 ms) | (< 9 ms) | (< 9 ms) | (< 9 ms) | (< 12 ms) (< 14 ms) |
Phase offset Phase is adjustable remotely [LAN, GPIB,
Sweep modes
Internal reference oscillator
Operating modes Frequency step, amplitude step and arbitrary list
Dwell time | 1 ms to 60 s |
| ||
|
|
|
| |
Number of points | 2 to 65,535 |
| ||
|
|
|
|
|
|
|
|
|
|
Stability3 |
|
|
| |
|
|
| Standard | With Option UNJ or 1E5 |
| Aging rate |
| < ±1 ppm/yr | < ±0.1 ppm/yr or |
|
|
|
| < ±0.0005 ppm/day after 45 days |
| Temp [0 to 55° C] | (< ±1 ppm) | (< ±0.05 ppm) | |
| Line voltage |
| (< ±0.1 ppm) | (< ±0.002 ppm) |
| Line voltage range | (+5% to | (+5% to | |
|
|
|
| |
RF reference output |
|
|
| |
| Frequency |
| 10 MHz |
|
| Amplitude |
| 4 dBm ±2 dB |
|
RF reference input requirements |
| ||
|
| Standard | With Option UNJ or 1E5 |
| Frequency | 1, 2, 5, 10 MHz ± 10 ppm | 1, 2, 5, 10 MHz ±.2 ppm |
| Amplitude |
|
|
| Input impedance | 50 Ω |
|
|
|
|
|
1.The E4438C is available as a vector platform only. For analog models refer to the E4428C.
2.Performance below 250 kHz not guaranteed.
3.Parentheses denote typical performance.
4.To within 0.1 ppm of final frequency above 250 MHz or within 100 Hz below 250 MHz.
5.Frequency switching time with the amplitude settled within ±0.1 dB.
5