Agilent Technologies E4440A manual Options and Accessories, Name, Description, Number, Chapter

Models: E4440A

1 84
Download 84 pages 39.65 Kb
Page 66
Image 66
Manual background

Options and Accessories

Options

 

 

Option

Name

Description

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

Secure Memory Erase

Provides the ability to quickly and easily perform a security

 

 

117

 

erase, deleting all user-stored data, without affecting the

 

 

 

useability of the analyzer. Option 117 cannot be installed if

 

 

 

 

 

 

 

 

Option 115 is installed.

 

 

 

 

 

 

 

122

80 MHz Bandwidth

Adds an alternative 80 MHz wide IF path for making

 

 

(E4440A,

Digitizer

measurements. Cannot be installed if Option 107 is installed.

 

 

 

Additional measurement accuracy can be achieved using the

 

 

43A, & 45A

 

 

 

 

External Calibration Wizard Option 235, or with the 89600

 

 

only)

 

 

 

 

Vector Signal Analyzer Application calibration. The 80 MHz

 

 

 

 

Accessories

 

 

 

functionality is available as part of the added Basic Mode. Basic

 

 

 

Mode includes the measurements:

 

 

 

 

 

 

 

 

spectrum (frequency domain)

 

 

 

 

waveform (time domain)

 

 

 

 

 

and

 

 

Switchable Preselector

Allows you to bypass the tuned filters at the input of the

 

 

Bypass

spectrum analyzer when making measurements in the

 

 

 

Options

 

 

 

3 to 50 GHz range. This improves the sensitivity and increases

 

 

 

signals to be visible on the display, in addition to the actual

 

 

123

 

the available measurement dynamic range. However it allows

 

 

 

the analyzers internal mixing products and image response

 

 

 

 

 

 

 

 

desired signal response. This option is available in all models.

 

 

 

 

Option 123 cannot be installed if Option AYZ is installed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y-axis Video Output

Provides a 0 to 1 V signal that corresponds to the bottom and

 

 

124

 

top of the display graticule, respectively. The output voltage

 

 

 

tracks the Y-axis position of the trace data while the analyzer is

 

 

 

 

 

 

 

 

sweeping. (This output is similar to the 8566B Video Out.)

 

 

 

 

 

 

 

140

40 MHz Bandwidth

Adds an alternative 40 MHz wide IF path for making

 

 

Digitizer

measurements. Cannot be installed if Option 107 is installed.

 

 

(E4440A,

 

The 40 MHz functionality is available as part of the added

 

 

 

Basic Mode. Basic Mode includes the measurements:

 

 

43A, & 45A

 

 

 

 

 

 

 

only)

 

spectrum (frequency domain)

 

 

 

 

waveform (time domain)

 

 

 

 

 

 

 

202

GSM with EDGE

General transmitter measurement:

 

 

 

Measurement Personality

transmit power

 

 

 

 

 

 

 

 

Provides GSM (GMSK modulation) transmitter measurements:

 

 

 

 

power vs. time

 

 

 

 

phase and frequency error

 

 

 

 

output RF spectrum

 

 

 

 

transmit band spurs

 

 

 

 

Provides EDGE (8PSK modulation) transmitter measurements:

 

 

 

 

EVM

 

 

 

 

power vs. time

 

 

 

 

output RF spectrum

 

 

 

 

transmit band spurs

 

 

 

 

Requires Option B7J hardware.

 

 

 

 

 

66

Chapter 5

Page 66
Image 66
Agilent Technologies E4440A manual Options and Accessories, Name, Description, Number, Chapter