The TERM CODE variable is made up of DEVSEL#, TRDY#, and

STOP#. The following lists the bit pattern and the corresponding symbol.

 

 

 

 

 

 

 

 

Symbol

DEVSEL#

TRDY#

STOP#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MASTER ABORT

1

1

1

 

 

 

 

 

 

 

 

SPLIT RESPONSE

1

0

1

 

 

 

 

 

 

 

 

TARGET ABORT

1

1

0

 

 

 

 

 

 

 

 

SINGLE DATA DISC

1

0

0

 

 

 

 

 

 

 

 

RETRY

0

1

0

 

 

 

 

 

 

 

 

DISC NXT ADB

0

0

0

 

 

 

 

 

 

The hardware layout of the FS2010 made it impossible for the signals to

Bit Re-orderingbe connected to the logic analyzer in a logical order. Therefore, bit re- ordering is done in the configuration file to make the data easier to view. The bit re-ordering function can be found in the FORMAT menu.

Below is a list of labels that have been re-ordered

ADDR

ADDR_B

STAT

AD_HI

AD_LO

C/B3_0

CYCLE

TERM CODE

20

Page 20
Image 20
Agilent Technologies FS2010 user manual Devsel# Trdy# Stop#