Section 7: Infrared Transmission System
7.2.2 Using the Infrared Receiver
Refer to fig. 10
on page 37.
!
1.Connect the headphones to the jack (1). Make sure to turn the VOLUME control (5) to its minimum posi- tion to avoid damaging your hearing by excessive sound levels.
2.To switch power to the receiver on, press the <ON> key (2) on the receiver side panel. The BATTERY LED (3) provides the following information:
LED… | Status | Required action |
|
|
|
…is lit green for 2 seconds after | Battery is adequately charged for | None. |
pressing <ON> , then flashes green. | normal operation. |
|
|
|
|
…starts flashing red. | Battery will be dead in about 15 | • Charge battery as soon as pos- |
| minutes. | sible. |
|
|
|
…remains dark after pressing <ON>. | • Battery is completely dis- | • Charge battery as soon as pos- |
| charged. | sible. |
| • There is no battery inside the | • Contact your nearest AKG Serv- |
| receiver | ice Center or Distributor. |
|
|
|
3.Use the LANGUAGE SELECT rotary switch (6) to select the desired language from the list of interpreted languages provided by the organizers (or by ear, if no such list is available).
4.Use the VOLUME control (5) to set the volume level of your headphones just loud enough so you can hear clearly what is being said.
Important:
•Do not turn the headphones volume up any higher than necessary. Listening to excessive sound lev- els on headphones may damage your hearing.
•(Refer to fig. 10 on page 37.) Never cover the collecting lens (4) above the infrared receiving diode. Cov- ering the lens (4) will cut the signal and may cause the receiver to switch off automatically.
Note: The signal may fade in some spots within the conference room due to interference or shadow effects. If that happens, move away from such a spot.
5.If the BATTERY LED (3) on the receiver top panel starts flashing, the battery will be dead soon. Return the receiver to conference staff. They will give you a receiver with a fully charged battery.
6.You cannot switch power to the receiver off. The receiver will switch off automatically 30 seconds after the infrared signal has stopped.
Note: The receiver will also switch off automatically before the battery is completely discharged to avoid damaging the battery.
7.2.3 Replacing Batteries
The infrared receiver is delivered with a 280 mAh 9 V NiMH rechargeable battery installed.
Important:
!• The battery cannot be replaced by the user. When the battery needs replacing, contact your nearest AKG Service Center or AKG Distributor.
CS 5 User Manual | - 39 - |