Section 2: Notes on Wiring and System Examples

2.2.2 Computer-controlled Discussion System

Example 2: Larger discussion system with computer control.

Example 2 above shows a larger discussion system with more than six microphone stations and computer control. To ensure stable powering even if one power supply fails, connect one CS 5 PS 12 power supply to the Base Unit, one CS 5 PS 12 power supply to every sixth microphone station, beginning with the seventh in line counting from the Base Unit, and connect the last microphone station to the second SYSTEM connector on the Base Unit.

The computer controlling the system is connected to the USB port on the Base Unit. In order to make optimum use of all the functions offered by computer control, we recommend using CS 5 VU microphone stations, although computer control will also work with CS 5 DU stations.

CS 5 User Manual

- 9 -

Page 9
Image 9
AKG Acoustics CS 5 Computer-controlled Discussion System, Example 2 Larger discussion system with computer control