Management Setup Menu
2-17Console Login Configuration
Use the Management Setup: Console Login Configuration to restrict management
access based on specified user names and passwords, or to set the invalid
password threshold and timeout. There are only two user types defined, ADMIN
(Administrator) and GUEST, but you can set up to five different user names and
passwords. Only Administrators have write access for parameters governing the
switch. You should therefore assign a user name and password to the default
Administrator as soon as possible, and store it in a safe place. (If for some reason
your password is lost, or you cannot gain access to the system configuration
program, contact Alcatel Technical Support for assistance.) The parameters shown
on this screen are indicated in the following figure and tab le.
Alcatel OmniStack 8008
< Console Login Configuration >
Password Threshold : 3
Lock-out Time (in minutes) : 0
User Type User Name Password Confirm password
----------------------------------------------------------
1. ADMIN admin ****** ******
2. GUEST guest
3.
4.
5
<APPLY> <OK> <CANCEL>
Use <TAB> or arrow keys to move, other keys to make changes.
Parameter Default Description
Password
Threshold
3 Sets the password intrusion threshold which limits the number
of failed logon attempts. Range : 0~65535
Lock-out
Time
0 Time (in minutes) the management console will be disabled,
Range : 0~65535
Admin* name: admin
password: switch
Administrator has access privilege of Read/Write for all
screens.
Guest* name: user
password: switch
Guest has access privilege of Read Only for all screens.
* Passwords can consist of up to 11 alphanumeric characters and are not case sensitive.