Programming

Explanation of the Step Functions

Fill:

Choose between 4 water inlet configurations and 3 water levels.

Water Inlet Configurations:

Cold:

Only opens the cold water valve.

Hot:

Only opens the hot water valve.

Warm:

Opens the cold and hot water valves.

Aux Fill: Opens an auxiliary water valve if installed.

Water Levels:

Low:

Low water level.

Med:

Medium water level.

High:

High water level.

The inlet configurations and the fill levels appear on the keypad, keys 1, 2, 3 and 8.

Be sure to select first the inlet configuration and then the water level.

Then you will be asked for the step time limit.

Example: Warm Low (time limit 5 minutes 30 seconds)

Step XX Cycle XX

Warm

Step XX Cycle XX

Warm Low

Step XX Cycle XX 0 min

Step XX Cycle XX 5 min 30 sec

NOTE: If a fill error occurs, then machine has

2 minutes to finish filling. If after 2 minutes it has not finished filling, cycle is aborted.

8

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9001889

Page 10
Image 10